Baessler, Bettina ORCID: 0000-0002-3244-3864, Treutlein, Melanie, Schaarschmidt, Frank, Stehning, Christian, Schnackenburg, Bernhard, Michels, Guido, Maintz, David and Bunck, Alexander C. (2017). A novel multiparametric imaging approach to acute myocarditis using T2-mapping and CMR feature tracking. J. Cardiov. Magn. Reson., 19. LONDON: BMC. ISSN 1532-429X

Full text not available from this repository.

Abstract

Background: The aim of this study was to evaluate the diagnostic potential of a novel cardiovascular magnetic resonance (CMR) based multiparametric imaging approach in suspected myocarditis and to compare it to traditional Lake Louise criteria (LLC). Methods: CMR data from 67 patients with suspected acute myocarditis were retrospectively analyzed. Seventeen age-and gender-matched healthy subjects served as control. T2-mapping data were acquired using a Gradient-Spin-Echo T2-mapping sequence in short-axis orientation. T2-maps were segmented according to the 16-segments AHA-model and segmental T2 values and pixel-standard deviation (SD) were recorded. Afterwards, the parameters maxT2 (the highest segmental T2 value) and madSD (the mean absolute deviation (MAD) of the pixel-SDs) were calculated for each subject. Cine sequences in three long axes and a stack of short-axis views covering the left and right ventricle were analyzed using a dedicated feature tracking algorithm. Results: A multiparametric imaging model containing madSD and LV global circumferential strain (GCS(LV)) resulted in the highest diagnostic performance in receiver operating curve analyses (area under the curve [AUC] 0.84) when compared to any model containing a single imaging parameter or to LLC (AUC 0.79). Adding late gadolinium enhancement (LGE) to the model resulted in a further increased diagnostic performance (AUC 0.93) and yielded the highest diagnostic sensitivity of 97% and specificity of 77%. Conclusions: A multiparametric CMR imaging model including the novel T2-mapping derived parameter madSD, the feature tracking derived strain parameter GCSLV and LGE yields superior diagnostic sensitivity in suspected acute myocarditis when compared to any imaging parameter alone and to LLC.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Baessler, BettinaUNSPECIFIEDorcid.org/0000-0002-3244-3864UNSPECIFIED
Treutlein, MelanieUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Schaarschmidt, FrankUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Stehning, ChristianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Schnackenburg, BernhardUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Michels, GuidoUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Maintz, DavidUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Bunck, Alexander C.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-217498
DOI: 10.1186/s12968-017-0387-x
Journal or Publication Title: J. Cardiov. Magn. Reson.
Volume: 19
Date: 2017
Publisher: BMC
Place of Publication: LONDON
ISSN: 1532-429X
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
CARDIAC MAGNETIC-RESONANCE; DIAGNOSTIC PERFORMANCE; CURRENT STATEMultiple languages
Cardiac & Cardiovascular Systems; Radiology, Nuclear Medicine & Medical ImagingMultiple languages
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/21749

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item