Enders, Philip and Cursiefen, Claus (2020). Device profile of the EYEMATE-IO (TM) system for intraocular pressure monitoring: overview of its safety and efficacy. Expert Rev. Med. Devices, 17 (6). S. 491 - 498. ABINGDON: TAYLOR & FRANCIS LTD. ISSN 1745-2422

Full text not available from this repository.

Abstract

Introduction: Assessment of intraocular pressure (IOP) is a core diagnostic tool in management of glaucoma. All established ways to measure IOP use indirect approaches through ocular tissues, mainly the cornea or the sclera. Telemetric IOP measurement with an implantable device could eliminate bias caused by indirect techniques and could allow continuous monitoring. A favorable safety profile, high efficacy and good tolerability are key requirements. Areas covered: The Eyemate-IO (TM) system (Implandata Ophthalmic Products GmbH, Hannover, Germany) is a novel CE-marked implantable medical device for direct measurement of IOP. It consists of an intraocular sensor ring and an external reading device. This review presents the mechanism of telemetric IOP measurement and summarizes the available clinical data. Twelve months follow-up data of two clinical trials provide support for the efficacy and safety of this device. Expert opinion: The implantable Eyemate-IO (TM) in keratoprosthesis was well tolerated; recorded adverse events were known complications of standalone surgery. The system had a good agreement with other IOP measuring modalities, including intraoperative manometry. In glaucoma patients, the Eyemate-IO (TM) could be implanted safely and showed a favorable efficacy and safety profile in the first twelve months postoperatively. The potential to achieve IOP monitoring with the Eyemate-IO (TM) seems promising.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Enders, PhilipUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Cursiefen, ClausUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-334116
DOI: 10.1080/17434440.2020.1761788
Journal or Publication Title: Expert Rev. Med. Devices
Volume: 17
Number: 6
Page Range: S. 491 - 498
Date: 2020
Publisher: TAYLOR & FRANCIS LTD
Place of Publication: ABINGDON
ISSN: 1745-2422
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
IOP TELEMETRY; GLAUCOMA; SENSOR; PATHOPHYSIOLOGY; IMPLANTATION; CONTACTMultiple languages
Engineering, BiomedicalMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/33411

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item