Weckmann, Julia, Scharf, Sven, Graf, Isabelle, Schwarze, Joerg, Keilig, Ludger, Bourauel, Christoph and Braumann, Bert (2020). Influence of attachment bonding protocol on precision of the attachment in aligner treatments. J. Orofac. Orthop., 81 (1). S. 30 - 41. MUNICH: URBAN & VOGEL. ISSN 1615-6714

Full text not available from this repository.

Abstract

Aim Precise bonding of attachments in aligner treatment is crucial to achieve the intended tooth movement. Thus, we evaluated five different bonding protocols for attachments used in aligner treatments with the goal of identifying the most precise protocol. Methods One ellipsoid and one rectangular attachment were exemplarily chosen and examined. All attachments were bonded using the same template aligner, which was produced by thermoforming. The bonding process was repeated 30 times with each protocol for statistical analysis. The protocols differed in the type of composite used (high viscous, low viscous), the additional application of a perforation in the attachment reservoir, and the use of a two-phase procedure with high viscous composite. All bonded attachments were laser scanned and compared to the attachments of a master model using a surface/surface matching algorithm to determine the precision, i.e., highest aberrations (maximum vertical distance) between the attachment of the master and results obtained from the various bonding protocols. Furthermore, the excessive amounts of composite bonded around the attachments were measured and compared. Results The two-phase procedure had a median aberration of 0.13mm and a median amount of excessive composite of 7.40mm(2) (ellipsoid attachment). With the low viscous composite without a perforation in the template reservoir, similar results were achieved (median 0.13mm) regarding the maximum vertical distance, but had an excess area of 33.50mm(2). Conclusion In this in vitro study, the bonding protocol influenced the precision of bonded attachments. The bonding protocol with high viscous composite without a perforation in the attachment reservoir was the most inaccurate. The use of a low viscous composite or attachments made by a two-phase procedure with high viscous composite revealed more precise results.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Weckmann, JuliaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Scharf, SvenUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Graf, IsabelleUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Schwarze, JoergUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Keilig, LudgerUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Bourauel, ChristophUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Braumann, BertUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-351589
DOI: 10.1007/s00056-019-00204-7
Journal or Publication Title: J. Orofac. Orthop.
Volume: 81
Number: 1
Page Range: S. 30 - 41
Date: 2020
Publisher: URBAN & VOGEL
Place of Publication: MUNICH
ISSN: 1615-6714
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
PERIODONTAL HEALTH; INVISALIGN; COMPOSITEMultiple languages
Dentistry, Oral Surgery & MedicineMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/35158

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item