Schymik, Gerhard, Rudolph, Tanja, Jacobshagen, Claudius, Rothe, Jurgen, Treede, Hendrik, Kerber, Sebastian, Frank, Derk, Sykorova, Lenka, Okamoto, Maki, Thoenes, Martin, Deutsch, Cornelia, Bramlage, Peter and Butter, Christian (2019). Balloon-expandable transfemoral transcatheter aortic valve implantation with or without predilation: findings from the prospective EASE-IT TF multicentre registry. Open Heart, 6 (2). LONDON: BMJ PUBLISHING GROUP. ISSN 2053-3624

Full text not available from this repository.

Abstract

Background Predilation of the native valve has long been deemed necessary in transfemoral transcatheter aortic valve implantation (TF-TAVI), despite little trial evidence to support its clinical use. As most evidence is derived from retrospective analyses of observational studies, we conducted a two-armed, prospective multicentre registry. Methods Patients undergoing TF-TAVI with the Edwards SAPIEN 3 valve, with or without balloon aortic valvuloplasty (BAV), were included and their procedural characteristics, short-term safety and short-term efficacy outcomes compared. We hypothesised that BAV may be safely omitted in many patients and omission could be associated with procedural benefits. Results Overall, 196 consecutive patients underwent TF-TAVI, 56 with BAV and 140 without. The mean age was 81.2 +/- 6.2 years, and the mean logistic EuroSCORE I was 17.1 +/- 13.6. Device success according to Valve Academic Research Consortium-2 (VARC-2) was achieved in 96.4%. The median procedural duration was shorter without BAV (56 min vs 90 min; p=0.001), as was fluoroscopy time (10 min vs 13 min; p=0.001). The need for balloon postdilation was less frequent in patients without BAV (15.7% vs 30.4%, p=0.029). There was no difference in the proportion of patients meeting the VARC-2 defined composite safety endpoint at 30 days (9.3% without vs 8.9% with BAV; adjusted OR (adjOR) 2.55; 95% CI 0.56 to 18.84) and at 6 months (15.2% without vs 16.4% with BAV; adjOR 1.66; 95% CI 0.49 to 6.55). Conclusions In the majority of patients, BAV can be safely omitted from the TAVI procedure without adverse effects. The omission of BAV is associated with shorter procedural duration and could be advantageous for the majority of patients.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Schymik, GerhardUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Rudolph, TanjaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Jacobshagen, ClaudiusUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Rothe, JurgenUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Treede, HendrikUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Kerber, SebastianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Frank, DerkUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Sykorova, LenkaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Okamoto, MakiUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Thoenes, MartinUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Deutsch, CorneliaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Bramlage, PeterUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Butter, ChristianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-141957
DOI: 10.1136/openhrt-2019-001082
Journal or Publication Title: Open Heart
Volume: 6
Number: 2
Date: 2019
Publisher: BMJ PUBLISHING GROUP
Place of Publication: LONDON
ISSN: 2053-3624
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
FEASIBILITY; DILATIONMultiple languages
Cardiac & Cardiovascular SystemsMultiple languages
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/14195