Siggel, Robert, Christofi, Eleftheria, Giasoumi, Fanouria, Adler, Werner ORCID: 0000-0001-9791-5407, Siebelmann, Sebastian, Bachmann, Bjoern, Cursiefen, Claus and Heindl, Ludwig M. (2019). Changes in Corneal Biomechanical Properties After Descemet Membrane Endothelial Keratoplasty. Cornea, 38 (8). S. 964 - 970. PHILADELPHIA: LIPPINCOTT WILLIAMS & WILKINS. ISSN 1536-4798

Full text not available from this repository.

Abstract

Purpose: To evaluate the course of corneal biomechanical properties (corneal hysteresis and corneal resistance factor) after Descemet membrane endothelial keratoplasty (DMEK) in patients with Fuchs endothelial dystrophy (FECD). Methods: In this prospective study, we consecutively included 49 patients with FECD with an indication for DMEK. Central corneal thickness, measured using the Oculus Pentacam, and corneal hysteresis (CH) and corneal resistance factor (CRF), both measured using the Reichert Ocular Response Analyzer, were examined preoperatively, 3 months, and 6 months after DMEK. Results: CH was significantly increased 6 months postoperatively (8.66 +/- 2.50 mm Hg) compared with preoperative baseline (7.43 +/- 1.56 mm Hg). Preoperative CRF (7.89 +/- 1.68 mm Hg) increased significantly 6 months after DMEK (8.49 +/- 1.71 mm Hg). Preoperative central corneal thickness showed a significant decrease from 629 +/- 58 mm to 550 +/- 40 mm after 3 months and 535 +/- 40 mm after 6 months postoperatively. Conclusions: DMEK affects both measured corneal biomechanical properties in patients with FECD: CH and CRF. This has to be taken into account for the accuracy of intraocular pressure measurements.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Siggel, RobertUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Christofi, EleftheriaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Giasoumi, FanouriaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Adler, WernerUNSPECIFIEDorcid.org/0000-0001-9791-5407UNSPECIFIED
Siebelmann, SebastianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Bachmann, BjoernUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Cursiefen, ClausUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Heindl, Ludwig M.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-145672
DOI: 10.1097/ICO.0000000000001986
Journal or Publication Title: Cornea
Volume: 38
Number: 8
Page Range: S. 964 - 970
Date: 2019
Publisher: LIPPINCOTT WILLIAMS & WILKINS
Place of Publication: PHILADELPHIA
ISSN: 1536-4798
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
DYNAMIC CONTOUR TONOMETRY; OCULAR-RESPONSE-ANALYZER; INTRAOCULAR-PRESSURE; THICKNESS; GOLDMANN; HYSTERESIS; TRANSPLANTATION; KERATOCONUS; DYSTROPHY; 1STMultiple languages
OphthalmologyMultiple languages
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/14567

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)