Kausar, Abu, Mani, Karthick R., Azhari, Hasin A. and Zakaria, Golam A. (2019). Patient-specific quality control for intensity-modulated radiation therapy and volumetric-modulated arc therapy using electronic portal imaging device and two-dimensional ion chamber array. J. Radiother. Pract., 18 (1). S. 26 - 32. CAMBRIDGE: CAMBRIDGE UNIV PRESS. ISSN 1467-1131
Full text not available from this repository.Abstract
AimThe purpose of this study was to develop the patient-specific quality control (QC) process by most commonly used dosimeters in Bangladesh and recommend a suitable passing rate for QC, irrespective of the dosimetric tools used.Materials and methodsIntensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) plans of five head-and-neck (HN) and five prostate patients were selected for the patient-specific QC. These plans were generated using the Eclipse TPS v110 (Varian Medical Systems, Inc., Palo Alto, CA, USA) 6 MV X-ray from a Varian TrueBeam linear accelerator (Varian Medical Systems, Inc.) for each case. Each IMRT and VMAT plans were measured by two-dimensional (2D) ion chamber arrays (I'matriXX) and electronic portal imaging devices (EPID), respectively. The passing rates of the dosimetric tools were calculated using criteria of 3%/3 mm.ResultsThe average passing rates (SD) of I'matriXX for prostate and HN were 979 +/- 076 and 9888 +/- 024, respectively. For VMAT verification, the average passing rates of EPID for prostate for arc1 and arc2 were 9615 +/- 049 and 978 +/- 070, respectively; similarly, for HN the rates were 9785 +/- 063 and 972 +/- 056, respectively.ConclusionThe results showed that both the dosimeters can be used in patient-specific QC, although the EPID-based IMRT and VMAT QC is more advantageous in terms of time-saving and ease of use. Hence, for patient-specific QC, one can use the ion chamber arrays (I'matriXX) or EPID in hospital, but the systems need to be cross-checked.
Item Type: | Journal Article | ||||||||||||||||||||
Creators: |
|
||||||||||||||||||||
URN: | urn:nbn:de:hbz:38-155755 | ||||||||||||||||||||
DOI: | 10.1017/S1460396918000328 | ||||||||||||||||||||
Journal or Publication Title: | J. Radiother. Pract. | ||||||||||||||||||||
Volume: | 18 | ||||||||||||||||||||
Number: | 1 | ||||||||||||||||||||
Page Range: | S. 26 - 32 | ||||||||||||||||||||
Date: | 2019 | ||||||||||||||||||||
Publisher: | CAMBRIDGE UNIV PRESS | ||||||||||||||||||||
Place of Publication: | CAMBRIDGE | ||||||||||||||||||||
ISSN: | 1467-1131 | ||||||||||||||||||||
Language: | English | ||||||||||||||||||||
Faculty: | Unspecified | ||||||||||||||||||||
Divisions: | Unspecified | ||||||||||||||||||||
Subjects: | no entry | ||||||||||||||||||||
Uncontrolled Keywords: |
|
||||||||||||||||||||
Refereed: | Yes | ||||||||||||||||||||
URI: | http://kups.ub.uni-koeln.de/id/eprint/15575 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
View Item |