Bastkowski, Rene, Weiss, Kilian ORCID: 0000-0003-4295-4585, Maintz, David and Giese, Daniel ORCID: 0000-0002-3925-4441 (2018). Self-gated golden-angle spiral 4D flow MRI. Magn. Reson. Med., 80 (3). S. 904 - 914. HOBOKEN: WILEY. ISSN 1522-2594

Full text not available from this repository.

Abstract

PurposeThe acquisition of 4D flow magnetic resonance imaging (MRI) in cardiovascular applications has recently made large progress toward clinical feasibility. The need for simultaneous compensation of cardiac and breathing motion still poses a challenge for widespread clinical use. Especially, breathing motion, addressed by gating approaches, can lead to unpredictable and long scan times. The current work proposes a time-efficient self-gated 4D flow sequence that exploits up to 100% of the acquired data and operates at a predictable scan time. MethodsA self-gated golden-angle spiral 4D flow sequence was implemented and tested in 10 volunteers. Data were retrospectively binned into respiratory and cardiac states and reconstructed using a conjugate-gradient sensitivity encoding reconstruction. Net flow curves, stroke volumes, and peak flow in the aorta were evaluated and compared to a conventional Cartesian 4D flow sequence. Additionally, flow quantities reconstructed from 50% to 100% of the self-gated 4D flow data were compared. ResultsSelf-gating signals for respiratory and cardiac motion were extracted for all volunteers. Flow quantities were in agreement with the standard Cartesian scan. Mean differences in stroke volumes and peak flow of 7.611.5 and 4.0 +/- 79.9mL/s were obtained, respectively. By retrospectively increasing breathing navigator efficiency while decreasing acquisition times (15:06-07:33 minutes), 50% of the acquired data were sufficient to measure stroke volumes with errors under 9.6mL. ConclusionThe feasibility to acquire respiratory and cardiac self-gated 4D flow data at a predictable scan time was demonstrated. Magn Reson Med 80:904-913, 2018. (c) 2018 International Society for Magnetic Resonance in Medicine.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Bastkowski, ReneUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Weiss, KilianUNSPECIFIEDorcid.org/0000-0003-4295-4585UNSPECIFIED
Maintz, DavidUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Giese, DanielUNSPECIFIEDorcid.org/0000-0002-3925-4441UNSPECIFIED
URN: urn:nbn:de:hbz:38-175900
DOI: 10.1002/mrm.27085
Journal or Publication Title: Magn. Reson. Med.
Volume: 80
Number: 3
Page Range: S. 904 - 914
Date: 2018
Publisher: WILEY
Place of Publication: HOBOKEN
ISSN: 1522-2594
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
CARDIOVASCULAR MAGNETIC-RESONANCE; PHASE-CONTRAST MRI; CARDIAC CINE MRI; RESPIRATORY MOTION; BLOOD-FLOW; STRATEGIES; QUANTIFICATION; TRAJECTORIES; ACQUISITION; ANGIOGRAPHYMultiple languages
Radiology, Nuclear Medicine & Medical ImagingMultiple languages
Refereed: Yes