Robinson, Samuel, Follo, Marie, Haenel, David, Mauler, Maximilian, Stallmann, Daniela, Andreas, Lukas Heger, Helbing, Thomas, Duerschmied, Daniel ORCID: 0000-0001-5249-4012, Peter, Karlheinz, Bode, Christoph, Ahrens, Ingo and Hortmann, Marcus (2018). Chip-based digital PCR as a novel detection method for quantifying microRNAs in acute myocardial infarction patients. Acta Pharmacol. Sin., 39 (7). S. 1217 - 1228. SHANGHAI: ACTA PHARMACOLOGICA SINICA. ISSN 1745-7254

Full text not available from this repository.

Abstract

miRNAs have shown promise as potential biomarkers for acute myocardial infarction (AMI). However, the current used quantitative real-time PCR (qRT-PCR) allows solely for relative expression of nucleic acids and it is susceptible to day-to-day variability, which has limited the validity of using the miRNAs as biomarkers. In this study we explored the technical qualities and diagnostic potential of a new technique, chip-based digital PCR, in quantifying the miRNAs in patients with AMI and ischaemia-reperfusion injury (I/R). In a dilution series of synthetic C elegans-miR-39, chip-based digital PCR displayed a lower coefficient of variation (8.9% vs 46.3%) and a lower limit of detection (0.2 copies/mu L vs 1.1 copies/mu L) compared with qRT-PCR. In the serum collected from 24 patients with ST-elevation myocardial infarction (STEMI) and 20 patients with stable coronary artery disease (CAD) patients after percutaneous coronary intervention (PCI), we used qRT-PCR and multiplexed chip-based digital PCR to quantify the serum levels of miRNA-21 and miRNA-499 as they have been validated in AMI in prior studies. In STEMI, I/R injury was assessed via measurement of ST-segment resolution (ST-R). Chip-based digital PCR revealed a statistical significance in the difference of miR-21 levels between stable CAD and STEMI groups (118.8 copies/mu L vs 59 copies/mu L; P=0.0300), whereas qRT-PCR was unable to reach significance (136.4 copies/mu L vs 122.8 copies/mu L; P=0.2273). For miR-499 levels, both chip-based digital PCR and qRT-PCR revealed statistically significant differences between stable CAD and STEMI groups (2 copies/mu L vs 8.5 copies/mu L, P=0.0011; 0 copies/mu L vs 19.4 copies/mu L; P<0.0001). There was no association between miR-21/499 levels and ST-R post-PCI. Our results show that the chip-based digital PCR exhibits superior technical qualities and promises to be a superior method for quantifying miRNA levels in the circulation, which may become a more accurate and reproducible method for directly quantifying miRNAs, particularly for use in large multi-centre clinical trials.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Robinson, SamuelUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Follo, MarieUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Haenel, DavidUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Mauler, MaximilianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Stallmann, DanielaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Andreas, Lukas HegerUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Helbing, ThomasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Duerschmied, DanielUNSPECIFIEDorcid.org/0000-0001-5249-4012UNSPECIFIED
Peter, KarlheinzUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Bode, ChristophUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Ahrens, IngoUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Hortmann, MarcusUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-181421
DOI: 10.1038/aps.2017.136
Journal or Publication Title: Acta Pharmacol. Sin.
Volume: 39
Number: 7
Page Range: S. 1217 - 1228
Date: 2018
Publisher: ACTA PHARMACOLOGICA SINICA
Place of Publication: SHANGHAI
ISSN: 1745-7254
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
ST-SEGMENT ELEVATION; CREATINE KINASE-MB; CIRCULATING MICRORNAS; QUANTIFICATION; QUANTITATION; EXPRESSION; BIOMARKERS; RESOLUTION; EFFICACYMultiple languages
Chemistry, Multidisciplinary; Pharmacology & PharmacyMultiple languages
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/18142

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item