Enders, Philip ORCID: 0000-0002-9527-4957, Adler, Werner ORCID: 0000-0001-9791-5407, Schaub, Friederike, Hermann, Manuel M., Diestelhorst, Michael, Dietlein, Thomas, Cursiefen, Claus and Heindl, Ludwig M. (2017). Optimization Strategies for Bruch's Membrane Opening Minimum Rim Area Calculation: Sequential versus Simultaneous Minimization. Sci Rep, 7. LONDON: NATURE PUBLISHING GROUP. ISSN 2045-2322

Full text not available from this repository.

Abstract

To compare a simultaneously optimized continuous minimum rim surface parameter between Bruch's membrane opening (BMO) and the internal limiting membrane to the standard sequential minimization used for calculating the BMO minimum rim area in spectral domain optical coherence tomography (SD-OCT). In this case-control, cross-sectional study, 704 eyes of 445 participants underwent SDOCT of the optic nerve head (ONH), visual field testing, and clinical examination. Globally and clockhour sector-wise optimized BMO-based minimum rim area was calculated independently. Outcome parameters included BMO-globally optimized minimum rim area (BMO-gMRA) and sector-wise optimized BMO-minimum rim area (BMO-MRA). BMO area was 1.89 +/- 0.05 mm(2). Mean global BMOMRA was 0.97 +/- 0.34 mm(2), mean global BMO-gMRA was 1.01 +/- 0.36 mm(2). Both parameters correlated with r = 0.995 (P < 0.001); mean difference was 0.04 mm(2) (P < 0.001). In all sectors, parameters differed by 3.0-4.2%. In receiver operating characteristics, the calculated area under the curve (AUC) to differentiate glaucoma was 0.873 for BMO-MRA, compared to 0.866 for BMO-gMRA (P = 0.004). Among ONH sectors, the temporal inferior location showed the highest AUC. Optimization strategies to calculate BMO-based minimum rim area led to significantly different results. Imposing an additional adjacency constraint within calculation of BMO-MRA does not improve diagnostic power. Global and temporal inferior BMO-MRA performed best in differentiating glaucoma patients.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Enders, PhilipUNSPECIFIEDorcid.org/0000-0002-9527-4957UNSPECIFIED
Adler, WernerUNSPECIFIEDorcid.org/0000-0001-9791-5407UNSPECIFIED
Schaub, FriederikeUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Hermann, Manuel M.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Diestelhorst, MichaelUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Dietlein, ThomasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Cursiefen, ClausUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Heindl, Ludwig M.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-213996
DOI: 10.1038/s41598-017-14284-1
Journal or Publication Title: Sci Rep
Volume: 7
Date: 2017
Publisher: NATURE PUBLISHING GROUP
Place of Publication: LONDON
ISSN: 2045-2322
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
OPTICAL COHERENCE TOMOGRAPHY; SCANNING LASER OPHTHALMOSCOPY; FIBER LAYER THICKNESS; DISC MARGIN ANATOMY; NERVE HEAD; GLAUCOMA; POLARIMETRY; POPULATION; PERIMETRYMultiple languages
Multidisciplinary SciencesMultiple languages
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/21399

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item