Linden, Katharina, Ladage, Dennis ORCID: 0000-0002-4512-0917, Dewald, Oliver, Gatzweiler, Eva ORCID: 0000-0002-2015-6673, Pieper, Andrea, Seehase, Matthias, Duerr, Georg Daniel, Breuer, Johannes and Herberg, Ulrike (2017). Comparison of stroke volumes assessed by three-dimensional echocardiography and transpulmonary thermodilution in a pediatric animal model. J. Clin. Monitor. Comp., 31 (2). S. 353 - 361. HEIDELBERG: SPRINGER HEIDELBERG. ISSN 1573-2614

Full text not available from this repository.

Abstract

To compare stroke volumes (SV) in small hearts assessed by real-time three-dimensional echocardiography (3DE) with SV measured by transpulmonary thermodilution (TPTD) and continuous pulse contour analysis (PC) under various hemodynamic conditions. In thirteen anesthetized piglets (range 3.6-7.1 kg) SV were measured by 3DE, TPTD and PC at baseline and during phenylephrine and esmolol administration. 3DE and TPTD measurements were done successively while SV calculated by PC was documented at the time of 3DE. 3DE and TPTD showed a good correlation (r(2) = 0.74) and a bias of -1.3 ml (limits of agreement -4.1 to 1.5 ml). While TPTD measured higher SV than 3DE, both methods tracked SV changes with a concordance rate of 91 %. PC and 3DE showed a lower correlation coefficient of r(2) = 0.57 and a bias of -2.1 ml (limits of agreement -5.9 to 1.8 ml). Inter- and intra-observer variability of SV measured by 3DE was good with a mean bias < 5 %. SV3DE showed a small variance and tracked acute small changes in SV in acceptable concordance with TPTD. PC measured SV with a higher variance and mean difference compared to 3DE. In an experimental setting 3DE has the possibility to offer non-invasive assessments of ventricular volumes volume changes. To determine whether 3DE could be used for SV assessment in a clinical routine our results need confirmation in a clinical setting.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Linden, KatharinaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Ladage, DennisUNSPECIFIEDorcid.org/0000-0002-4512-0917UNSPECIFIED
Dewald, OliverUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Gatzweiler, EvaUNSPECIFIEDorcid.org/0000-0002-2015-6673UNSPECIFIED
Pieper, AndreaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Seehase, MatthiasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Duerr, Georg DanielUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Breuer, JohannesUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Herberg, UlrikeUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-235605
DOI: 10.1007/s10877-016-9843-7
Journal or Publication Title: J. Clin. Monitor. Comp.
Volume: 31
Number: 2
Page Range: S. 353 - 361
Date: 2017
Publisher: SPRINGER HEIDELBERG
Place of Publication: HEIDELBERG
ISSN: 1573-2614
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
CARDIAC-OUTPUT MEASUREMENT; CONGENITAL HEART-DISEASE; LEFT-VENTRICULAR INDEXES; MAGNETIC-RESONANCE; VENTILATED CHILDREN; EJECTION FRACTION; DIRECT FICK; VALIDATION; INFANTS; FEASIBILITYMultiple languages
AnesthesiologyMultiple languages
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/23560

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item