Mazzitelli, Domenico, Fischlein, Theodor, Rankin, J. Scott, Choi, Yeong-Hoon, Stamm, Christof, Pfeiffer, Steffen, Pirk, Jan, Detter, Christian, Kroll, Johannes, Beyersdorf, Friedhelm ORCID: 0000-0003-2975-2751, Griffin, Charles D., Shrestha, Malakh, Noebauer, Christian, Crooke, Philip S., Schreiber, Christian and Lange, Ruediger (2016). Geometric ring annuloplasty as an adjunct to aortic valve repair: clinical investigation of the HAART 300 device. Eur. J. Cardio-Thorac. Surg., 49 (3). S. 987 - 994. CARY: OXFORD UNIV PRESS INC. ISSN 1873-734X

Full text not available from this repository.

Abstract

This study assessed the safety and efficacy of an internal geometric annuloplasty ring in a regulatory trial of aortic valve reconstruction (ClinicalTrials.gov Identifier: NCT01400841). Sixty-five patients with predominant moderate-to-severe trileaflet aortic insufficiency (AI) underwent aortic valve repair with an average age of 63 +/- 13 years (mean +/- SD). All had initial implantation of an internal aortic annuloplasty ring to correct annular dilatation and facilitate leaflet reconstruction. Leaflet plication was performed for prolapse in 80% of patients, and more complex leaflet procedures, usually employing autologous pericardium, were required in 22%. Ascending aortic and/or root aneurysms were replaced in 62%. Follow-up was for a maximum of 3 years and a mean of 2 years. No in-hospital operative mortalities, major complications or early or late valve-related events occurred. The annular diameter before repair was 26.5 +/- 2.3 mm, and the average ring diameter used was 21.5 +/- 1.6 mm. The preoperative AI grade (0-4) was 2.9 +/- 0.8 and improved after repair to 0.6 +/- 0.7 (P < 0.0001), as did the NYHA class. The mean valve gradient was 8.6 +/- 4.3 mmHg, and at 3 years, the Kaplan-Meier survival rate was 95%, with no valve-related mortality. Over the 3 years, aortic valve replacement was required in 7 patients (10.8%) for reasons usually related to surgical technique. Most repair failures occurred early, and results stabilized after 6 months. No structural complications of the rings were observed. Geometric ring annuloplasty was a safe and effective adjunct to aortic valve repair. Initial correction of annular dilatation seemed to facilitate overall reconstruction. Because most early repair failures were technical, increasing experience with geometric ring annuloplasty for aortic valve reconstruction has the potential to standardize and improve outcomes.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Mazzitelli, DomenicoUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Fischlein, TheodorUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Rankin, J. ScottUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Choi, Yeong-HoonUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Stamm, ChristofUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Pfeiffer, SteffenUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Pirk, JanUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Detter, ChristianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Kroll, JohannesUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Beyersdorf, FriedhelmUNSPECIFIEDorcid.org/0000-0003-2975-2751UNSPECIFIED
Griffin, Charles D.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Shrestha, MalakhUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Noebauer, ChristianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Crooke, Philip S.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Schreiber, ChristianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Lange, RuedigerUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-283651
DOI: 10.1093/ejcts/ezv234
Journal or Publication Title: Eur. J. Cardio-Thorac. Surg.
Volume: 49
Number: 3
Page Range: S. 987 - 994
Date: 2016
Publisher: OXFORD UNIV PRESS INC
Place of Publication: CARY
ISSN: 1873-734X
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
RECONSTRUCTION; SURGERY; REGURGITATION; REPLACEMENT; MORTALITYMultiple languages
Cardiac & Cardiovascular Systems; Respiratory System; SurgeryMultiple languages
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/28365

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item