Siebelmann, Sebastian, Steven, Philipp, Hos, Deniz, Huettmann, Gereon, Lankenau, Eva, Bachmann, Bjoern and Cursiefen, Claus (2016). Advantages of microscope-integrated intraoperative online optical coherence tomography: usage in Boston keratoprosthesis type I surgery. J. Biomed. Opt., 21 (1). BELLINGHAM: SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS. ISSN 1560-2281
Full text not available from this repository.Abstract
Boston keratoprosthesis (KPro) type I is a technique to treat patients with corneal diseases that are not amenable to conventional keratoplasty. Correct assembly and central implantation of the prosthesis are crucial for postoperative visual recovery. This study investigates the potential benefit of intraoperative optical coherence tomography (OCT) to monitor KPro surgery. Retrospective case series are presented for two patients who underwent Boston KPro type I implantation. The surgery in both patients was monitored intraoperatively using a commercially available intraoperative OCT (iOCT) device mounted on a surgical microscope. Microscope-integrated intraoperative OCT was able to evaluate the correct assembly and implantation of the KPro. All parts of the prosthesis were visible, and interfaces between the corneal graft and titanium backplate or anterior optics were clearly depictable. Moreover, iOCT visualized a gap between the backplate and graft in one case, and in the other case, a gap between the anterior optic and graft. Neither gap was visible with a conventional surgical microscope. The gap between the anterior optic and the graft could easily be corrected. Microscope-integrated iOCT delivers enhanced information, adding to the normal surgical microscope view during KPro surgery. Correct assembly can be controlled as well as the correct placement of the Boston KPro into the anterior chamber. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
Item Type: | Journal Article | ||||||||||||||||||||||||||||||||
Creators: |
|
||||||||||||||||||||||||||||||||
URN: | urn:nbn:de:hbz:38-289534 | ||||||||||||||||||||||||||||||||
DOI: | 10.1117/1.JBO.21.1.016005 | ||||||||||||||||||||||||||||||||
Journal or Publication Title: | J. Biomed. Opt. | ||||||||||||||||||||||||||||||||
Volume: | 21 | ||||||||||||||||||||||||||||||||
Number: | 1 | ||||||||||||||||||||||||||||||||
Date: | 2016 | ||||||||||||||||||||||||||||||||
Publisher: | SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS | ||||||||||||||||||||||||||||||||
Place of Publication: | BELLINGHAM | ||||||||||||||||||||||||||||||||
ISSN: | 1560-2281 | ||||||||||||||||||||||||||||||||
Language: | English | ||||||||||||||||||||||||||||||||
Faculty: | Unspecified | ||||||||||||||||||||||||||||||||
Divisions: | Unspecified | ||||||||||||||||||||||||||||||||
Subjects: | no entry | ||||||||||||||||||||||||||||||||
Uncontrolled Keywords: |
|
||||||||||||||||||||||||||||||||
Refereed: | Yes | ||||||||||||||||||||||||||||||||
URI: | http://kups.ub.uni-koeln.de/id/eprint/28953 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
View Item |