Oikonomidis, Stavros, Grevenstein, David, Yagdiran, Ayla, Scheyerer, Max Joseph, Eh, Madita, Wegmann, Kilian, Eysel, Peer and Sircar, Krishnan (2020). Probe versus drill: A biomechanical evaluation of two different pedicle preparation techniques for pedicle screw fixation in human cadaveric osteoporotic spine. Clin. Biomech., 75. OXFORD: ELSEVIER SCI LTD. ISSN 1879-1271
Full text not available from this repository.Abstract
Background: Aim of this biomechanical study was to investigate the anchorage of pedicle screws in osteoporotic vertebrae using two different preparation techniques (probe versus drill-assisted). Methods: Twelve thoracic vertebrae were used for the study. The right and left pedicles of the vertebra were prepared with a thoracic probe or a 3.2 mm drill bit and divided into two groups. A standard titanium (diameter: 5.5 mm, length: 45 mm) pedicle screw was then inserted. All pedicle screws were initially loaded with - 25 N to + 25 N in the cranio-caudal direction. The load was increased by 5 N every 500 cycles up to a maximum load of 10,000 cycles. Loosening was defined as a displacement of the pedicle screw head of > 5 mm. The two groups were compared in terms of maximum number of cycles and maximum force until loosening. Findings: The pedicle screws prepared with the thoracic probe failed on average after 3819 cycles (SD 3281) and the pedicle screws prepared with the 3.2 mm drill after 3335 cycles (SD 3477). There was no significant difference between the two preparation techniques (P = .797). With regard to the maximum force until loosening, there was also no significant difference between the two techniques (thoracic probe: 61 N (SD 33), 3.2 mm drill bit 56 N (SD 34), P = .791). Interpretation: Preparation of the pedicle screw hole either with a probe or drill bit doesn't seem to have an influence on pedicle screw loosening rates in the osteoporotic spine.
Item Type: | Journal Article | ||||||||||||||||||||||||||||||||||||
Creators: |
|
||||||||||||||||||||||||||||||||||||
URN: | urn:nbn:de:hbz:38-335404 | ||||||||||||||||||||||||||||||||||||
DOI: | 10.1016/j.clinbiomech.2020.104997 | ||||||||||||||||||||||||||||||||||||
Journal or Publication Title: | Clin. Biomech. | ||||||||||||||||||||||||||||||||||||
Volume: | 75 | ||||||||||||||||||||||||||||||||||||
Date: | 2020 | ||||||||||||||||||||||||||||||||||||
Publisher: | ELSEVIER SCI LTD | ||||||||||||||||||||||||||||||||||||
Place of Publication: | OXFORD | ||||||||||||||||||||||||||||||||||||
ISSN: | 1879-1271 | ||||||||||||||||||||||||||||||||||||
Language: | English | ||||||||||||||||||||||||||||||||||||
Faculty: | Unspecified | ||||||||||||||||||||||||||||||||||||
Divisions: | Unspecified | ||||||||||||||||||||||||||||||||||||
Subjects: | no entry | ||||||||||||||||||||||||||||||||||||
Uncontrolled Keywords: |
|
||||||||||||||||||||||||||||||||||||
URI: | http://kups.ub.uni-koeln.de/id/eprint/33540 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
View Item |