Schmitt, Daniela ORCID: 0000-0002-9657-0715, Blanck, Oliver ORCID: 0000-0003-1391-1308, Gauer, Tobias, Fix, Michael K., Brunner, Thomas B., Fleckenstein, Jens, Loutfi-Krauss, Britta, Manser, Peter, Werner, Rene, Wilhelm, Maria-Lisa, Baus, Wolfgang W. and Moustakis, Christos (2020). Technological quality requirements for stereotactic radiotherapy Expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. Strahlenther. Onkol., 196 (5). S. 421 - 444. HEIDELBERG: SPRINGER HEIDELBERG. ISSN 1439-099X
Full text not available from this repository.Abstract
This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings.
Item Type: | Journal Article | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Creators: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
URN: | urn:nbn:de:hbz:38-340373 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
DOI: | 10.1007/s00066-020-01583-2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Journal or Publication Title: | Strahlenther. Onkol. | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Volume: | 196 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Number: | 5 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Page Range: | S. 421 - 444 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Date: | 2020 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Publisher: | SPRINGER HEIDELBERG | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Place of Publication: | HEIDELBERG | ||||||||||||||||||||||||||||||||||||||||||||||||||||
ISSN: | 1439-099X | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Language: | English | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Faculty: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Divisions: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Subjects: | no entry | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Uncontrolled Keywords: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
URI: | http://kups.ub.uni-koeln.de/id/eprint/34037 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
View Item |