Houbois, Christian, Haneder, Stefan, Merkt, Martin, Holz, Jasmin A., Morelli, John, Kiel, Alexandra, Doerner, Jonas, Maintz, David and Puesken, Michael (2020). Semiautomated Renal Cortex Volumetry in Multislice Computed Tomography: Effect of Slice Thickness and Iterative Reconstruction Algorithms. J. Comput. Assist. Tomogr., 44 (2). S. 236 - 242. PHILADELPHIA: LIPPINCOTT WILLIAMS & WILKINS. ISSN 1532-3145

Full text not available from this repository.

Abstract

Objective The aim of the study was to evaluate the effect of slice thickness, iterative reconstruction (IR) algorithm, and kernel selection on measurement accuracy and interobserver variability for semiautomated renal cortex volumetry (RCV) with multislice computed tomography (CT). Methods Ten patients (62.4 +/- 17.2 years) undergoing abdominal biphasic multislice computed tomography were enrolled in this retrospective study. Computed tomography data sets were reconstructed at 1-, 2-, and 5-mm slice thickness with 2 different IR algorithms (iDose, IMRST) and 2 different kernels (IMRS and IMRR) (Philips, the Netherlands). Two readers independently performed semiautomated RCV for each reconstructed data set to calculate left kidney volume (LKV) and split renal function (SRF). Statistics were calculated using analysis of variance with Geisser-Greenhouse correction, followed by Tukey multiple comparisons post hoc test. Statistical significance was defined as P <= 0.05. Results Semiautomated RCV of 120 data sets (240 kidneys) was successfully performed by both readers. Semiautomated RCV provides comparable results for LKV and SRF with 3 different slice thicknesses, 2 different IR algorithms, and 2 different kernels. Only the 1-mm slice thickness showed significant differences for LKV between IMRR and IMRS (P = 0.02, mean difference = 4.28 bb) and IMRST versus IMRS (P = 0.02, mean difference = 4.68 cm(3)) for reader 2. Interobserver variability was low between both readers irrespective of slice thickness and reconstruction algorithm (0.82 >= P >= 0.99). Conclusions Semiautomated RCV measurements of LKV and SRF are independent of slice thickness, IR algorithm, and kernel selection. These findings suggest that comparisons between studies using different slice thicknesses and reconstruction algorithms for RCV are valid.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Houbois, ChristianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Haneder, StefanUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Merkt, MartinUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Holz, Jasmin A.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Morelli, JohnUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Kiel, AlexandraUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Doerner, JonasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Maintz, DavidUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Puesken, MichaelUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-342326
DOI: 10.1097/RCT.0000000000000988
Journal or Publication Title: J. Comput. Assist. Tomogr.
Volume: 44
Number: 2
Page Range: S. 236 - 242
Date: 2020
Publisher: LIPPINCOTT WILLIAMS & WILKINS
Place of Publication: PHILADELPHIA
ISSN: 1532-3145
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
PULMONARY NODULES; AUTOMATED VOLUMETRY; NUCLEAR-RENOGRAPHY; CT VOLUMETRY; SEGMENTATION; PREDICTION; DONORSMultiple languages
Radiology, Nuclear Medicine & Medical ImagingMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/34232

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item