Laukamp, Kai Roman ORCID: 0000-0002-5600-5914, Lennartz, Simon, Ho, Vivian, Hokamp, Nils Grosse, Zopfs, David ORCID: 0000-0001-9978-7453, Gupta, Amit, Graner, Frank Philipp, Borggrefe, Jan ORCID: 0000-0003-2908-7560, Gilkeson, Robert and Ramaiya, Nikhil (2020). Evaluation of the liver with virtual non-contrast: single institution study in 149 patients undergoing TAVR planning. Br. J. Radiol., 93 (1106). LONDON: BRITISH INST RADIOLOGY. ISSN 1748-880X
Full text not available from this repository.Abstract
Objective: To evaluate accuracy of virtual-non-contrast images (VNC) compared to true-unenhanced-images (TNC) for evaluation of liver attenuation acquired using spectral-detector CT (SDCT). Methods: 149 patients who underwent multiphase transcatheter-aortic-valve-replacement (TAVR) SDCT-examinations [unenhanced-chest (TNC), CT-angiography chest (CTA-chest, early arterial-phase) and abdomen (CTA-abdomen, additional early arterial-phase after a second injection of contrast media)] were retrospectively included. VNC of CTA-chest (VNC-chest) and CTA-abdomen (VNC-abdomen) were reconstructed and compared to TNC. Region of interest-based measurement of mean attenuation (Hounsfield unit, HU) was applied in the following regions: liver, spleen, abdominal aorta and paraspinal muscle. Results: VNC accuracy was high in the liver, spleen, abdominal aorta and muscle for abdomen-scanning. For the liver, average attenuation was 59.0 +/- 9.1 HU for TNC and 72.6 +/- 9,5 HU for CTA-abdomen. Liver attenuation in VNC-abdomen (59.1 +/- 6.4 HU) was not significantly different from attenuation in TNC (p > 0.05). In contrast, VNC was less accurate for chest-scanning: Due to the protocol, in CTA-chest no contrast media was present in the liver parenchyma as indicated by the same attenuation in TNC (59.0 +/- 9.1 HU) and CTA-chest (58.8 +/- 8.9 HU, p > 0.05). Liver attenuation in VNC-chest (56.2 +/- 6.4 HU, p < 0.05) was, however, significantly lower than in TNC and CTA-chest implying an artificial reduction of attenuation. Conclusion: VNC performed well in a large cohort of TAVR-examinations yielding equivalent mean attenuations to TNC; however, application of this technique might be limited when no or very little contrast media is present in parenchyma, more precisely in an early arterial-phase of the liver. Advances in knowledge: This study showed that VNC can be reliably applied in cardiac protocols when certain limitations are considered
Item Type: | Journal Article | ||||||||||||||||||||||||||||||||||||||||||||
Creators: |
|
||||||||||||||||||||||||||||||||||||||||||||
URN: | urn:nbn:de:hbz:38-351512 | ||||||||||||||||||||||||||||||||||||||||||||
DOI: | 10.1259/bjr.20190701 | ||||||||||||||||||||||||||||||||||||||||||||
Journal or Publication Title: | Br. J. Radiol. | ||||||||||||||||||||||||||||||||||||||||||||
Volume: | 93 | ||||||||||||||||||||||||||||||||||||||||||||
Number: | 1106 | ||||||||||||||||||||||||||||||||||||||||||||
Date: | 2020 | ||||||||||||||||||||||||||||||||||||||||||||
Publisher: | BRITISH INST RADIOLOGY | ||||||||||||||||||||||||||||||||||||||||||||
Place of Publication: | LONDON | ||||||||||||||||||||||||||||||||||||||||||||
ISSN: | 1748-880X | ||||||||||||||||||||||||||||||||||||||||||||
Language: | English | ||||||||||||||||||||||||||||||||||||||||||||
Faculty: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||
Divisions: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||
Subjects: | no entry | ||||||||||||||||||||||||||||||||||||||||||||
Uncontrolled Keywords: |
|
||||||||||||||||||||||||||||||||||||||||||||
URI: | http://kups.ub.uni-koeln.de/id/eprint/35151 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
View Item |