Wegmann, Kilian, Hain, Moritz K., Ries, Christian, Neiss, Wolfram F., Mueller, Lars P. and Burkhart, Klaus J. (2015). Do the radial head prosthesis components fit with the anatomical structures of the proximal radioulnar joint? Surg. Radiol. Anat., 37 (7). S. 743 - 748. PARIS: SPRINGER FRANCE. ISSN 1279-8517

Full text not available from this repository.

Abstract

The fitting accuracy of radial head components has been investigated in the capitulo-radial joint, and reduced contact after prosthetic replacement of the radial head has been observed. The kinematics of the proximal radioulnar joint (PRUJ) are affected by radial head arthroplasty as well, but have not yet been investigated in this regard. The elbow joints of 60 upper extremities of formalin-fixed body donors were disarticulated to obtain a good view of the PRUJ. Each specimen was mounted on the examining table and radial head position in the native PRUJ was assessed in neutral position, full pronation, and full supination. Measurements were repeated after implantation of mono- and bi-polar prostheses. Analysis of the distribution of the joint contacts in the compartments showed significant differences after radial head replacement. In comparison to the native joint, after bipolar and monopolar radial head replacement, the physiological shift of the proximal radius was altered. The physiological shift of the joint contact of the radial head from anterior to posterior during forearm rotation that was found in the native joint in our cadaver model was not observed after prosthetic replacement. With higher conformity and physiological kinematic of radial head prostheses, possibly lower shear forces and lower contact pressures would be generated. The tested radial head prostheses do not replicate the physiological kinematics of the radial head. Further development in the prosthesis design has to be made. The meticulous reconstruction of the annular ligament seems to be of importance to increase joint contact.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Wegmann, KilianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Hain, Moritz K.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Ries, ChristianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Neiss, Wolfram F.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Mueller, Lars P.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Burkhart, Klaus J.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-394878
DOI: 10.1007/s00276-014-1407-2
Journal or Publication Title: Surg. Radiol. Anat.
Volume: 37
Number: 7
Page Range: S. 743 - 748
Date: 2015
Publisher: SPRINGER FRANCE
Place of Publication: PARIS
ISSN: 1279-8517
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
ARTHROPLASTY; FRACTURESMultiple languages
Anatomy & Morphology; Radiology, Nuclear Medicine & Medical Imaging; SurgeryMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/39487

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item