Oppermann, Johannes, Wacker, Max, Stein, Gregor ORCID: 0000-0002-0443-4573, Springorum, Hans-Philipp, Neiss, Wolfram Friedrich, Burkhart, Klaus J., Eysel, Peer and Dargel, Jens (2014). Anatomical fit of seven different palmar distal radius plates. Arch. Orthop. Trauma Surg., 134 (10). S. 1483 - 1490. NEW YORK: SPRINGER. ISSN 1434-3916

Full text not available from this repository.

Abstract

The purpose of this study was to compare the anatomical fit of different, precontoured palmar distal radius plates. The anatomical fit of seven different types of palmar distal radius plates [Konigsee variable fixed-angle radius plate 7/3-hole, Konigsee variable fixed-angle radius plate 5/3-hole (Allendorf, Germany), Medartis 2.5 Adaptive TriLock, Medartis 2.5 TriLock, Medartis 2.5 TriLock extraarticular, (Basel, Switzerland), Synthes VA-LCP distal two-column-radius, Synthes LCP extraarticular (Bettlach, Switzerland)] were investigated in 25 embalmed human cadaveric radii. An imprint of the space between the well-positioned plate and the distal radius was attained using a silicone mass and the maximum height of the silicone imprint was digitally measured. The mean maximum imprint height was compared between the seven plates using an analysis of variance with repeated measures and Bonferroni correction for multiple comparisons. The mean maximum distance between the plates and the radial cortex was < 2 mm for all plates. The greatest difference was found with the Medartis Adaptive (1.99 +/- A 0.45 mm) and the least difference with the Synthes two-column (1.56 +/- A 0.76 mm), this difference being statistically significant (p = 0.005). Although there was no complete congruency between the plates and the radial cortex, all distal palmar radius plates investigated in this study presented a reasonable anatomical shape. The Synthes VA-LCP distal two-column-radius plate palmar showed the best anatomical fit. A low profile and optimized anatomical precontouring minimizes irritation of the surrounding soft tissues and should be considered with plate design and implant choice.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Oppermann, JohannesUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Wacker, MaxUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Stein, GregorUNSPECIFIEDorcid.org/0000-0002-0443-4573UNSPECIFIED
Springorum, Hans-PhilippUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Neiss, Wolfram FriedrichUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Burkhart, Klaus J.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Eysel, PeerUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Dargel, JensUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-427571
DOI: 10.1007/s00402-014-2072-y
Journal or Publication Title: Arch. Orthop. Trauma Surg.
Volume: 134
Number: 10
Page Range: S. 1483 - 1490
Date: 2014
Publisher: SPRINGER
Place of Publication: NEW YORK
ISSN: 1434-3916
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
VOLAR LOCKING PLATES; PRONATOR QUADRATUS REPAIR; FLEXOR POLLICIS LONGUS; LOW-PROFILE DORSAL; INTERNAL-FIXATION; FRACTURE FIXATION; ANGLE; COMPLICATIONS; TENDON; OSTEOSYNTHESISMultiple languages
Orthopedics; SurgeryMultiple languages