Verhoeven, E. L. G., Katsargyris, A., Bachoo, P., Larzon, T., Fisher, R., Ettles, D., Boyle, J. R., Brunkwall, J., Boeckler, D., Florek, H-J, Stella, A., Kasprzak, P., Verhagen, H. and Riambau, V. (2014). Real-world Performance of the New C3 Gore Excluder Stent-Graft: 1-year Results from the European C3 Module of the Global Registry for Endovascular Aortic Treatment (GREAT). Eur. J. Vasc. Endovasc. Surg., 48 (2). S. 131 - 138. LONDON: W B SAUNDERS CO LTD. ISSN 1532-2165
Full text not available from this repository.Abstract
Objectives: The European C3 module of the Global Registry for Endovascular Aortic Treatment (GREAT) provides real-world outcomes for the new C3 Gore Excluder stent-graft, and evaluates the new deployment mechanism. This report presents the 1-year results from 400 patients enrolled in this registry. Methods: Between August 2010 and December 2012, 400 patients (86.8% male, mean age 73.9 +/- 7.8 years) from 13 European sites were enrolled in this registry. Patient demographics, treatment indication, case planning, operative details including repositioning and technical results, and clinical outcome were analyzed. Results: Technical success was achieved in 396/400 (99%) patients. Two patients needed intraoperative open conversion, one for iliac rupture, the second because the stent-graft was pulled down during a cross-over catheterization in an angulated anatomy. Two patients required an unplanned chimney renal stent to treat partial coverage of the left renal artery because of upward displacement of the stent-graft. Graft repositioning occurred in 192/399 (48.1%) patients, most frequently for level readjustment with regard to the renal arteries, and less commonly for contralateral gate reorientation. Final intended position of the stent-graft below the renal arteries was achieved in 96.2% of patients. Thirty-day mortality was two (0.5%) patients. Early reintervention (<= 30 days) was required in two (0.5%) patients. Mean follow-up duration was 15.9 +/- 8.8 months (range 0-37 months). Late reintervention (>30 days) was required in 26 (6.5%) patients. Estimated freedom from reintervention at 1 year was 95.2% (95% CI 92.3-97%), and at 2 years 91.5% (95% CI 86.8-94.5%). Estimated patient survival at 1 year was 96% (95% CI 93.3-97.6%) and at 2 years 90.6% (95% CI 85.6-93.9%). Conclusions: Early real-world experience shows that the new C3 delivery system offers advantages in terms of device repositioning resulting in high deployment accuracy. Longer follow-up is required to confirm that this high deployment accuracy results in improved long-term durability. (C) 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Item Type: | Journal Article | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Creators: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
URN: | urn:nbn:de:hbz:38-433272 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DOI: | 10.1016/j.ejvs.2014.04.009 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Journal or Publication Title: | Eur. J. Vasc. Endovasc. Surg. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Volume: | 48 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Number: | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Page Range: | S. 131 - 138 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Date: | 2014 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Publisher: | W B SAUNDERS CO LTD | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Place of Publication: | LONDON | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ISSN: | 1532-2165 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Language: | English | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Faculty: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Divisions: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Subjects: | no entry | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Uncontrolled Keywords: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
URI: | http://kups.ub.uni-koeln.de/id/eprint/43327 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
View Item |