Schmage, Petra, Kahili, Fisnik, Nergiz, Ibrahim, Scorziello, Thomas M., Platzer, Ursula and Pfeiffer, Peter (2014). Cleaning Effectiveness of Implant Prophylaxis Instruments. Int. J. Oral Maxillofac. Implants, 29 (2). S. 331 - 338. HANOVER PARK: QUINTESSENCE PUBLISHING CO INC. ISSN 1942-4434

Full text not available from this repository.

Abstract

Purpose: The aim of this study was to evaluate the cleaning effectiveness of implant prophylaxis instruments on polished and acid-etched implant surfaces. Materials and Methods: Biofilm layers of Streptococcus mutans were grown on a total of 80 titanium disks; 40 disks were polished and 40 were acid-etched. Five disks of each surface were cleaned using each of seven implant prophylaxis instruments: (1) manual plastic curette, (2) manual carbon fiber-reinforced plastic (CFRP) curette, (3) sonic-driven prophylaxis brush, (4) rotating rubber cup with prophylaxis paste, (5) sonic-driven polyether ether ketone (PEEK) plastic tip, (6) ultrasonic-driven PEEK plastic tip, and (7) air polishing with amino acid (glycine) powder. Ten disks (five of each surface type) served as controls. After cleaning, the surfaces with remaining bacteria were assessed by light microscopy. Statistical analyses of the results were performed with one-way and two-way analyses of variance with Bonferroni-Dunn multiple comparisons post hoc analysis (alpha = .05). Results: The cleaning effectiveness of the plastic curette was significantly lower than those of all machine-driven instruments on the polished surface. Significantly lower cleaning effectiveness occurred with the CFRP curette compared to the prophylaxis brush and to both oscillating PEEK plastic tips on the polished surface. The rubber cup provided less cleaning effectiveness compared to the ultrasonic PEEK plastic tip and air polishing on the acid-etched surface. Superior results, with less than 4% of the biofilm remaining, were obtained for both oscillating PEEK plastic tips and air polishing on both implant surfaces. The cleaning ability of the prophylaxis brush, rubber cup, and ultrasonic PEEK plastic tip differed significantly between both surface structures. Conclusions: Cleaning effectiveness, ie, less than 4% of the biofilm remaining, was not observed with all tested implant prophylaxis instruments. The cleaning ability of the devices depended on the implant surface structure.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Schmage, PetraUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Kahili, FisnikUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Nergiz, IbrahimUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Scorziello, Thomas M.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Platzer, UrsulaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Pfeiffer, PeterUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-444383
DOI: 10.11607/jomi.2524
Journal or Publication Title: Int. J. Oral Maxillofac. Implants
Volume: 29
Number: 2
Page Range: S. 331 - 338
Date: 2014
Publisher: QUINTESSENCE PUBLISHING CO INC
Place of Publication: HANOVER PARK
ISSN: 1942-4434
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
PERI-IMPLANTITIS; IN-VITRO; TITANIUM SURFACES; DENTAL IMPLANTS; BACTERIAL ADHESION; GLYCINE POWDER; ORAL IMPLANTS; THERAPY; ABUTMENTS; DECONTAMINATIONMultiple languages
Dentistry, Oral Surgery & MedicineMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/44438

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item