Coppi, G., Njila, M., Coppi, G., Saitta, G., Silingardi, R., Pratesi, C., Chiesa, R., Scheinert, D., Brunkwall, J. S. and Torsello, G. (2014). INCRAFT (R) Stent-Graft System: one-year outcome of the INNOVATION Trial. J. Cardiovasc. Surg., 55 (1). S. 51 - 60. TURIN: EDIZIONI MINERVA MEDICA. ISSN 1827-191X

Full text not available from this repository.

Abstract

Aim. Endovascular repair has surpassed open surgical treatment as the most common procedure in patients with abdominal aortic aneurysms (AAA), yet its applicability remains limited to those with aortoiliac anatomy suitable for the introduction and deployment of the devices. The current study was performed to assess the safety and efficacy of INCRAFT (R) (Cordis Corporation, Bridgewater, NJ), an ultra-low-profile device for the treatment of AAA. Methods. The INNOVATION study is a first in human prospective, multicenter trial involving 6 centers in Europe. From March 2010 to June 2011 60 patients with asymptomatic AAA were treated with the INCRAFT bifurcated Stent-Graft System. The main inclusion criteria were a proximal aortic neck of 15 mm or more in length and up to 27 mm in diameter; iliac landing zones greater than 10 mm in length and between 9 and 18 mm in diameter; an access vessel large enough to accept the 14F outer diameter of the delivery system; and an aortic bifurcation >18 mm in diameter. The primary endpoint was technical success at one-month; one-year safety endpoints included the absence of device- or procedure-related major adverse events; absence of type I or III endoleaks; and maintenance of device integrity through one year of follow-up. Results. Among 60 patients treated at six centers, the primary endpoint was met in 56 of 58 patients (97%; 95% CI, 88-100%) who came back for one month follow-up, two patients did not come back for their one month follow-up assessments but remained enrolled in the study. Fifty-six had one-year follow-up data showing 100% freedom from aneurysm enlargement with absence of type I and III endoleaks in all patients. There were two patients (3.6%) with a type Ia endoleak which was successfully treated with secondary endovascular intervention in both occasions. Core laboratory evaluation of the postoperative imaging studies documented absence of endograft migration, stent fracture, or limb occlusion. A single patient (1.8%) died within one year due to sepsis unrelated to the AAA. Conclusion. The results of the INNOVATION study with the INCRAFT Stent-Graft are encouraging, with satisfactory clinical outcome and device durability through one-year of follow-up. The INCRAFT device is a novel ultra-low-profile endograft that holds promise to broaden the patient population eligible for endovascular aneurysm repair.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Coppi, G.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Njila, M.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Coppi, G.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Saitta, G.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Silingardi, R.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Pratesi, C.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Chiesa, R.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Scheinert, D.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Brunkwall, J. S.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Torsello, G.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-447018
Journal or Publication Title: J. Cardiovasc. Surg.
Volume: 55
Number: 1
Page Range: S. 51 - 60
Date: 2014
Publisher: EDIZIONI MINERVA MEDICA
Place of Publication: TURIN
ISSN: 1827-191X
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
ENDOVASCULAR ANEURYSM REPAIRMultiple languages
Cardiac & Cardiovascular Systems; Surgery; Peripheral Vascular DiseaseMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/44701

Downloads

Downloads per month over past year

Export

Actions (login required)

View Item View Item