Milzi, Andrea, Dettori, Rosalia, Burgmaier, Kathrin, Marx, Nikolaus, Reith, Sebastian and Burgmaier, Mathias (2021). Quantitative Flow Ratio Is Related to Intraluminal Coronary Stenosis Parameters as Assessed with Optical Coherence Tomography. J. Clin. Med., 10 (9). BASEL: MDPI. ISSN 2077-0383

Full text not available from this repository.

Abstract

Background: Quantitative flow ratio (QFR) is a novel method for assessing hemodynamic relevance of a coronary lesion based on angiographic projections without the need of a pressure wire. Various studies demonstrated that QFR consistently related to fractional flow reserve (FFR); however, it is still unclear to what extent QFR reflects intraluminal stenosis parameters. Given that optical coherence tomography (OCT) is currently the gold standard to assess intraluminal stenosis parameters, we investigated the relationship between OCT-derived lesion geometry and QFR. Methods: We determined QFR in 97 lesions from 87 patients who underwent coronary angiography and OCT due to stable angina. QFR was measured with proprietary software and compared with OCT-based assessment of intraluminal stenosis parameters as well as lesion morphology. Results: Mean QFR was 0.79 +/- 0.10. QFR demonstrated a consistent association with FFR (r = 0.834, p < 0.001). Interestingly, QFR was associated with OCT-derived parameters such as minimal lumen area (MLA, r = 0.390, p = 0.015), percent area stenosis (r = 0.412, p < 0.001), minimal lumen diameter (MLD, r = 0.395, p < 0.001), and percent diameter stenosis (r = 0.400, p < 0.001). Both minimal luminal area (ROC = 0.734, optimal cut-off 1.75 mm(2)) and minimal luminal diameter (ROC = 0.714, optimal cut-off 1.59 mm) presented a good diagnostic accuracy in diagnosing hemodynamic relevance (QFR <= 0.80). There was no significant association between QFR and anatomic features of plaque vulnerability. Conclusion: OCT-derived intraluminal stenosis parameters are related to QFR values and predict hemodynamic lesion relevance. The data supports the validity of QFR as 3D-vessel reconstruction method to assess coronary physiology without the need of a pressure wire.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Milzi, AndreaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Dettori, RosaliaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Burgmaier, KathrinUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Marx, NikolausUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Reith, SebastianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Burgmaier, MathiasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-576255
DOI: 10.3390/jcm10091856
Journal or Publication Title: J. Clin. Med.
Volume: 10
Number: 9
Date: 2021
Publisher: MDPI
Place of Publication: BASEL
ISSN: 2077-0383
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
DIAGNOSTIC-ACCURACY; ANGIOGRAPHY; CRITERIA; RESERVE; RELEVANCEMultiple languages
Medicine, General & InternalMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/57625

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item