Useini, Dritan, Schlomicher, Markus, Beluli, Blerta, Christ, Hildegard, Ewais, Elias, Haldenwang, Peter, Patsalis, Polykarpos, Moustafine, Vadim, Bechtel, Matthias and Strauch, Justus (2021). Transapical-transcatheter aortic valve implantation using the Edwards SAPIEN 3 valve. J. Cardiovasc. Surg., 62 (6). S. 609 - 618. TURIN: EDIZIONI MINERVA MEDICA. ISSN 1827-191X
Full text not available from this repository.Abstract
BACKGROUND: Scarcely any data has been published on the mid-term effect of transapical-transcatheter aortic valve implantation (TA-TAVI) using the Edwards SAPIEN 3 valve (S3; Edwards Lifesciences Corp., Irvine, CA, USA). We present mid-term clinical and echocardiographic outcomes after TA-TAVI utilizing S3. METHODS: Between 02/2014-06/2017, 122 elderly patients with severe aortic stenosis underwent TA-TAVI utilizing S3 at our institution. We conducted clinical and echocardiographic follow-up. The mean follow-up was 15 months. All end-point-related outcomes were adjudicated ac-cording to Valve Academic Research Consortium-2 definitions. RESULTS: The STS-score of the entire cohort was 6.26 +/- 4.6. More than one-third of the patients exhibited severe peripheral artery disease. The 30-d all-cause mortality, all-stroke rate, and myocardial infarction of the entire cohort were 4.1%, 1.6%, and 0.8% respectively. Median survival time of the entire cohort was 35 months. The cumulative mid-term myocardial infarction and stroke rate was 2.6% and 3.5%, respectively. The postoperative moderate/severe paravalvular leakage occurred in 1.6% of cases. At discharge, one-year and two-year postprocedure peak/mean gradients were 16.6 +/- 8.3/ 9 +/- 5.1 mmHg, 18 +/- 6.9/ 10 +/- 4.5 mmHg, and 22.2 +/- 5.4/ 12.8 +/- 4.6 mmHg, respectively. The rate of new pacemaker cases was 14.1%. Acute kidney injury network 2/3 appears, as an independent predictor of mortality. CONCLUSIONS: We observed very promising early and mid-term clinical outcomes with a high degree of device success and good hemody-namic performance after TA-TAVI using the S3 in the intermediate risk patient profile. (Cite this article as: Useini D, Schlomicher M, Beluli B, Christ H, Ewais E, Haldenwang P, et al. Transapical-transcatheter aortic valve implantation the Edwards SAPIEN 3 valve. J Cardiovasc DOI: 10.23736/S0021
Item Type: | Journal Article | ||||||||||||||||||||||||||||||||||||||||||||
Creators: |
|
||||||||||||||||||||||||||||||||||||||||||||
URN: | urn:nbn:de:hbz:38-579499 | ||||||||||||||||||||||||||||||||||||||||||||
DOI: | 10.23736/S0021-9509.21.11523-X | ||||||||||||||||||||||||||||||||||||||||||||
Journal or Publication Title: | J. Cardiovasc. Surg. | ||||||||||||||||||||||||||||||||||||||||||||
Volume: | 62 | ||||||||||||||||||||||||||||||||||||||||||||
Number: | 6 | ||||||||||||||||||||||||||||||||||||||||||||
Page Range: | S. 609 - 618 | ||||||||||||||||||||||||||||||||||||||||||||
Date: | 2021 | ||||||||||||||||||||||||||||||||||||||||||||
Publisher: | EDIZIONI MINERVA MEDICA | ||||||||||||||||||||||||||||||||||||||||||||
Place of Publication: | TURIN | ||||||||||||||||||||||||||||||||||||||||||||
ISSN: | 1827-191X | ||||||||||||||||||||||||||||||||||||||||||||
Language: | English | ||||||||||||||||||||||||||||||||||||||||||||
Faculty: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||
Divisions: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||
Subjects: | no entry | ||||||||||||||||||||||||||||||||||||||||||||
Uncontrolled Keywords: |
|
||||||||||||||||||||||||||||||||||||||||||||
URI: | http://kups.ub.uni-koeln.de/id/eprint/57949 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
View Item |