Wiedmann, Isabella, Grassi, Marcello, Duran, Ibrahim ORCID: 0000-0003-4044-8822, Lavrador, Ricardo, Alberg, Evelyn, Daumer, Martin, Schoenau, Eckhard and Rittweger, Joern (2021). Accelerometric Gait Analysis Devices in Children-Will They Accept Them? Results From the AVAPed Study. Front. Pediatr., 8. LAUSANNE: FRONTIERS MEDIA SA. ISSN 2296-2360

Full text not available from this repository.

Abstract

Aims: To assess children's acceptance to wear a 3D-accelerometer which is attached to the waist under real-world conditions, and also to compare gait speed during supervised testing with the non-supervised gait speed in every-day life. Methods: In a controlled observational, cross sectional study thirty subjects with cerebral palsy (CP), with level I&II of the Gross Motor Function Classification System (GMFCS) and 30 healthy control children (Ctrl), aged 3-12 years, were asked to perform a 1-min-walking test (1 mwt) under laboratory conditions, and to wear an accelerometric device for a 1-week wearing home measurement (1 WHM). Acceptance was measured via wearing time, and by a questionnaire in which subjects rated restrictions in their daily living and wearing comfort. In addition, validity of 3D-accelerometric gait speed was checked through gold standard assessment of gait speed with a mobile perambulator. Results: Wearing time amounted to 10.3 (SD 3.4) hours per day, which was comparable between groups (T = 1.10, P = 0.3). Mode for wearing comfort [CP 1, Range (1,4), Ctrl 1, Range (1,6)] and restriction of daily living [CP 1, Range (1,3), Ctrl 1, Range (1,4)] was comparable between groups. Under laboratory conditions, Ctrl walked faster in the 1 mwt than CP (Ctrl 1.72 +/- 0.29 m/s, CP 1.48 +/- 0.41 m/s, P = 0.018). Similarly, a statistically significant difference was found when comparing real-world walking speed and laboratory walking speed (CP: 1 mwt 1.48 +/- 0.41 m/s, 1 WHM 0.89 +/- 0.09 m/s, P = 0.012; Ctrl: 1mwt 1.72 +/- 0.29, 1 WHM 0.97 +/- 0.06, P < 0.001). Conclusion: 3D-accelerometry is well-enough accepted in a pediatric population of patients with CP and a Ctrl group to allow valid assessments. Assessment outside the laboratory environment yields information about real world activity that was not captured by routine clinical tests. This suggests that assessment of habitual activities by wearable devices reflects the functioning of children in their home environment. This novel information constitutes an important goal for rehabilitation medicine. The study is registered at the German Register of Clinical Trials with the title Acceptance and Validity of 3D Accelerometric Gait Analysis in Pediatric Patients (AVAPed; DRKS00011919).

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Wiedmann, IsabellaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Grassi, MarcelloUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Duran, IbrahimUNSPECIFIEDorcid.org/0000-0003-4044-8822UNSPECIFIED
Lavrador, RicardoUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Alberg, EvelynUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Daumer, MartinUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Schoenau, EckhardUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Rittweger, JoernUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-589369
DOI: 10.3389/fped.2020.574443
Journal or Publication Title: Front. Pediatr.
Volume: 8
Date: 2021
Publisher: FRONTIERS MEDIA SA
Place of Publication: LAUSANNE
ISSN: 2296-2360
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
PediatricsMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/58936

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item