Williams, Gwendolyn, Thyagaraj, Suraj, Fu, Audrey, Oshinski, John, Giese, Daniel, Bunck, Alexander C., Fornari, Eleonora, Santini, Francesco ORCID: 0000-0001-6984-4816, Luciano, Mark, Loth, Francis and Martin, Bryn A. (2021). In vitro evaluation of cerebrospinal fluid velocity measurement in type I Chiari malformation: repeatability, reproducibility, and agreement using 2D phase contrast and 4D flow MRI. Fluids Barriers CNS, 18 (1). LONDON: BMC. ISSN 2045-8118

Full text not available from this repository.

Abstract

Background Phase contrast magnetic resonance imaging, PC MRI, is a valuable tool allowing for non-invasive quantification of CSF dynamics, but has lacked adoption in clinical practice for Chiari malformation diagnostics. To improve these diagnostic practices, a better understanding of PC MRI based measurement agreement, repeatability, and reproducibility of CSF dynamics is needed. Methods An anatomically realistic in vitro subject specific model of a Chiari malformation patient was scanned three times at five different scanning centers using 2D PC MRI and 4D Flow techniques to quantify intra-scanner repeatability, inter-scanner reproducibility, and agreement between imaging modalities. Peak systolic CSF velocities were measured at nine axial planes using 2D PC MRI, which were then compared to 4D Flow peak systolic velocity measurements extracted at those exact axial positions along the model. Results Comparison of measurement results showed good overall agreement of CSF velocity detection between 2D PC MRI and 4D Flow (p = 0.86), fair intra-scanner repeatability (confidence intervals +/- 1.5 cm/s), and poor inter-scanner reproducibility. On average, 4D Flow measurements had a larger variability than 2D PC MRI measurements (standard deviations 1.83 and 1.04 cm/s, respectively). Conclusion Agreement, repeatability, and reproducibility of 2D PC MRI and 4D Flow detection of peak CSF velocities was quantified using a patient-specific in vitro model of Chiari malformation. In combination, the greatest factor leading to measurement inconsistency was determined to be a lack of reproducibility between different MRI centers. Overall, these findings may help lead to better understanding for application of 2D PC MRI and 4D Flow techniques as diagnostic tools for CSF dynamics quantification in Chiari malformation and related diseases.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Williams, GwendolynUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Thyagaraj, SurajUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Fu, AudreyUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Oshinski, JohnUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Giese, DanielUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Bunck, Alexander C.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Fornari, EleonoraUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Santini, FrancescoUNSPECIFIEDorcid.org/0000-0001-6984-4816UNSPECIFIED
Luciano, MarkUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Loth, FrancisUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Martin, Bryn A.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-599138
DOI: 10.1186/s12987-021-00246-3
Journal or Publication Title: Fluids Barriers CNS
Volume: 18
Number: 1
Date: 2021
Publisher: BMC
Place of Publication: LONDON
ISSN: 2045-8118
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
NeurosciencesMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/59913

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item