Ries, Christian, Baltin, Christoph Tobias, Haneder, Stefan, Eysel, Peer, Hellmich, Martin and Boese, Christoph Kolja (2023). Dual-scale single marker calibration for digital templating of total hip arthroplasty in standing radiographs: a prospective clinical study. Arch. Orthop. Trauma Surg., 143 (4). S. 1817 - 1825. NEW YORK: SPRINGER. ISSN 1434-3916

Full text not available from this repository.

Abstract

Purpose Accuracy of calibration of radiographs significantly influences the quality of digital templating for total hip arthroplasty (THA). The standard of care is calibration with external calibration markers (ECM). This method is associated with significant errors. Dual-scale single marker (DSSM) calibration methods may improve accuracy. The present prospective observational study is the first to analyze the application of a DSSM method in standing pelvis radiographs. Methods 100 patients with unilateral THA underwent antero-posterior pelvis radiographs with ECM and DSSM. The hip components were used as reference calibration factor (internal calibration factor; ICM). Absolute differences of calibration factors for ECM and DSSM from ICM were calculated. Absolute relative deviations (ARD) were calculated. Subgroup analysis for sex and WHO BMI category was performed. Furthermore, patients reported subjective comfort for each marker using a 10-point scale and choosing the preferred marker. Results Maximum magnification factor differences from the ICM were 23.3% and 9.5% and mean absolute differences were 12.5% and 2.1% for the ECM and DSSM, respectively. ARD from ICM was significantly lower for DSSM compared to ECM (p < 0.001). Absolute differences increased with BMI category using ECM; calibration by DSSM was consistent in all subgroups. Patients preferred DSSM over ECM (n = 53) or were indifferent (n = 20). Comfort was rated significantly higher for DSSM versus ECM (p < 0.001). Conclusion DSSM method showed superior results in comparison to the ECM method for calibration of digital radiographs. DSSM could be used to improve digital templating in standing radiographs.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Ries, ChristianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Baltin, Christoph TobiasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Haneder, StefanUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Eysel, PeerUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Hellmich, MartinUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Boese, Christoph KoljaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-672728
DOI: 10.1007/s00402-022-04355-y
Journal or Publication Title: Arch. Orthop. Trauma Surg.
Volume: 143
Number: 4
Page Range: S. 1817 - 1825
Date: 2023
Publisher: SPRINGER
Place of Publication: NEW YORK
ISSN: 1434-3916
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
MAGNIFICATIONMultiple languages
Orthopedics; SurgeryMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/67272

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item