Luetkens, K. S., Hu, H., Kunz, A. S., Ritschl, L., Herbst, M., Kappler, S., Erguen, S., Goertz, L., Pennig, L., Bley, T. A., Gassenmaier, T. and Grunz, J. -P. (2022). The effect of tin prefiltration on extremity cone-beam CT imaging with a twin robotic X-ray system. Radiography, 28 (2). S. 433 - 440. OXFORD: ELSEVIER SCI LTD. ISSN 1532-2831

Full text not available from this repository.

Abstract

Introduction: While tin prefiltration is established in various CT applications, its value in extremity cone beam CT relative to optimized spectra has not been thoroughly assessed thus far. This study aims to investigate the effect of tin filters in extremity cone-beam CT with a twin-robotic X-ray system. Methods: Wrist, elbow and ankle joints of two cadaveric specimens were examined in a laboratory setup with different combinations of prefiltration (copper, tin), tube voltage and current-time product. Image quality was assessed subjectively by five radiologists with Fleiss' kappa being computed to measure interrater agreement. To provide a semiquantitative criterion for image quality, contrast-to-noise ratios (CNR) were compared for standardized regions of interest. Volume CT dose indices were calculated for a 16 cm polymethylmethacrylate phantom. Results: Radiation dose ranged from 17.4 mGy in the clinical standard protocol without tin filter to as low as 0.7 mGy with tin prefiltration. Image quality ratings and CNR for tin-filtered scans with 100 kV were lower than for 80 kV studies with copper prefiltration despite higher dose (11.2 and 5.6 vs. 4.5 mGy; p < 0.001). No difference was ascertained between 100 kV scans with tin filtration and 60 kV copper filtered scans with 75% dose reduction (subjective: p = 0.101; CNR: p = 0.706). Fleiss' kappa of 0.597 (95% confidence interval 0.567-0.626; p < 0.001) indicated moderate interrater agreement. Conclusion: Considerable dose reduction is feasible with tin prefiltration, however, the twin-robotic Xray system's low-dose potential for extremity 3D imaging is maximized with a dedicated low-kilovolt scan protocol in situations without extensive beam-hardening artifacts. Implications for practice: Low-kilovolt imaging with copper prefiltration provides a superior trade-off between dose reduction and image quality compared to tin-filtered cone-beam CT scan protocols with higher tube voltage. (c) 2021 The Author(s). Published by Elsevier Ltd on behalf of The College of Radiographers. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Luetkens, K. S.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Hu, H.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Kunz, A. S.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Ritschl, L.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Herbst, M.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Kappler, S.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Erguen, S.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Goertz, L.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Pennig, L.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Bley, T. A.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Gassenmaier, T.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Grunz, J. -P.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-676167
DOI: 10.1016/j.radi.2021.10.009
Journal or Publication Title: Radiography
Volume: 28
Number: 2
Page Range: S. 433 - 440
Date: 2022
Publisher: ELSEVIER SCI LTD
Place of Publication: OXFORD
ISSN: 1532-2831
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
COMPUTED-TOMOGRAPHY; QUALITY; OPTIMIZATION; FRACTURES; WRIST; BONEMultiple languages
Radiology, Nuclear Medicine & Medical ImagingMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/67616

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item