Egenolf, Philipp, Wasseq, Dorothee, Scheyerer, Max Joseph, Prescher, Andreas, Wegmann, Kilian, Mueller, Lars Peter, Eysel, Peer and Otto-Lambertz, Christina (2023). Is the rod necessary? Biomechanical comparison of static knee spacers during axial loading. Clin. Biomech., 101. OXFORD: ELSEVIER SCI LTD. ISSN 1879-1271

Full text not available from this repository.

Abstract

Background: Knee Spacers are required in two-stage revision surgery of periprosthetic joint infection of the knee. Extended bone and ligamentous defects are often temporarily arthrodised via a static spacer. Regarding their weight-bearing potential and construction, there is no current consent. Our aim was to evaluate three individual static spacer variants with regard to their axial loading capacity. Methods: The static spacer variants were tested in a cadaver model. One after the other, a spacer with metal -reinforced rods, a spacer without metal reinforcement and a rod-less spacer were implanted and tested up to an axial loading of 1000 Newton. Target parameters were plastic deformation, stiffness and spacer movement at both the femoral and tibial surface. Loading was applied up to 1000 Newton. Radiological controls of the bone substance were performed. Findings: The spacer variants did not differ regarding deformation, stiffness or spacer movement. However, deformation increased significantly with the axial load in all spacer variants. Radiographs showed no fracture or spacer-dislocation resulting from testing. Interpretation: While the spacer reinforcement or the sheer presence of a rod did not influence the axial loading capacity in this in vitro study, weightbearing should be discouraged to limit further bone erosion.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Egenolf, PhilippUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Wasseq, DorotheeUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Scheyerer, Max JosephUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Prescher, AndreasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Wegmann, KilianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Mueller, Lars PeterUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Eysel, PeerUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Otto-Lambertz, ChristinaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-677078
DOI: 10.1016/j.clinbiomech.2022.105867
Journal or Publication Title: Clin. Biomech.
Volume: 101
Date: 2023
Publisher: ELSEVIER SCI LTD
Place of Publication: OXFORD
ISSN: 1879-1271
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
2-STAGE REVISION; SEVERE BONEMultiple languages
Engineering, Biomedical; Orthopedics; Sport SciencesMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/67707

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item