Patzer, Theresa Sophie ORCID: 0000-0001-6169-1552, Grunz, Jan-Peter ORCID: 0000-0002-4524-1620, Huflage, Henner ORCID: 0000-0002-2784-3257, Conrads, Nora, Veldhoen, Simon ORCID: 0000-0002-3585-5442, Schmalzl, Jonas, Pennig, Lenhard, Bley, Thorsten Alexander, Luetkens, Karsten Sebastian and Kunz, Andreas Steven (2022). Combining gantry-free cone-beam computed tomography with iterative metal artefact reduction for surgical follow-up imaging of the appendicular skeleton. Eur. J. Radiol., 155. CLARE: ELSEVIER IRELAND LTD. ISSN 1872-7727
Full text not available from this repository.Abstract
Purpose: Post-surgical evaluation of osteosynthesis material and adjacent tissue can be challenging in both radiography and cross-sectional imaging. This study investigates the performance of a multi-purpose X-ray scanner with cone-beam CT (CBCT) function and iterative metal artefact reduction capabilities in patients after osteoplasty of the appendicular skeleton.Method: Eighty individuals who underwent both conventional X-ray imaging and CBCT after osteoplasty of the hand/wrist (48), elbow (14), or ankle/foot (18) with the gantry-free twin robotic system were retrospectively enrolled. Radiological reports from clinical routine for both imaging modalities were retrospectively analyzed and compared with consensus expert reading by two musculoskeletal specialists serving as the standard of reference. Findings of screw dislocation or implant loosening, fragment displacement, and delayed healing were compared between X-ray and CBCT reports using the McNemar test.Results: The median dose-area-product of CBCT and X-ray scans amounted to 27.98 and 0.2 dGy*cm(2), respectively. Diagnostic accuracy for screw dislocation was superior in CBCT compared to standard radiograms (98.8 % vs 83.8 %; p = 0.002). Implant loosening (98.8 % vs 86.3 %; p = 0.006), fragment displacement (98.8 % vs 85.0 %; p < 0.001), and delayed healing (97.5 % vs 88.8 %; p = 0.016) were also more reliably detected in CBCT. Employing CBCT, postoperative complications were detected with a sensitivity and specificity of at least 95.8 % and 98.1 %, compared to 33.3 % and 92.86 % in radiography.Conclusions: With superior accuracy for various osteoplasty-related complications, the CBCT scan mode of a gantry-free twin robotic X-ray system with iterative metal artefact reduction aids post-surgical assessment in the appendicular skeleton.
Item Type: | Journal Article | ||||||||||||||||||||||||||||||||||||||||||||
Creators: |
|
||||||||||||||||||||||||||||||||||||||||||||
URN: | urn:nbn:de:hbz:38-683030 | ||||||||||||||||||||||||||||||||||||||||||||
DOI: | 10.1016/j.ejrad.2022.110465 | ||||||||||||||||||||||||||||||||||||||||||||
Journal or Publication Title: | Eur. J. Radiol. | ||||||||||||||||||||||||||||||||||||||||||||
Volume: | 155 | ||||||||||||||||||||||||||||||||||||||||||||
Date: | 2022 | ||||||||||||||||||||||||||||||||||||||||||||
Publisher: | ELSEVIER IRELAND LTD | ||||||||||||||||||||||||||||||||||||||||||||
Place of Publication: | CLARE | ||||||||||||||||||||||||||||||||||||||||||||
ISSN: | 1872-7727 | ||||||||||||||||||||||||||||||||||||||||||||
Language: | English | ||||||||||||||||||||||||||||||||||||||||||||
Faculty: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||
Divisions: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||
Subjects: | no entry | ||||||||||||||||||||||||||||||||||||||||||||
Uncontrolled Keywords: |
|
||||||||||||||||||||||||||||||||||||||||||||
URI: | http://kups.ub.uni-koeln.de/id/eprint/68303 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
View Item |