Goertz, Lukas
ORCID: 0000-0002-2620-7611, Liebig, Thomas, Siebert, Eberhard, Zopfs, David
ORCID: 0000-0001-9978-7453, Pennig, Lenhard
ORCID: 0000-0002-6606-9313, Pflaeging, Muriel, Schlamann, Marc
ORCID: 0000-0002-7734-611X, Radomi, Alexandra, Dorn, Franziska and Kabbasch, Christoph
ORCID: 0000-0003-3712-2258
(2024).
Lessons learned from 12 years using the Woven Endobridge for the treatment of cerebral aneurysms in a multi-center series.
Scientific Reports, 14 (1).
pp. 1-11.
Springer Nature.
ISSN 2045-2322
|
PDF
s41598-024-75064-2.pdf Bereitstellung unter der CC-Lizenz: Creative Commons Attribution. Download (4MB) |
Abstract
[Artikel-Nr.: 24212] Intrasaccular flow disruption with the Woven Endobridge (WEB) has become a well-established endovascular technique for the treatment of intracranial aneurysms. This study presents our 12-year experience with the WEB and evaluates its evolving indications, procedures, and outcomes. A consecutive series of 324 aneurysms treated with WEB between 2011 and 2023 at three neurovascular centers was retrospectively analyzed and the study group was divided into four treatment periods. Uni- and multivariate analyses were performed to evaluate factors associated with technical success, thromboembolic complications, and angiographic outcome. The mean aneurysm size was 7.0 ± 3.6 mm and decreased during the study period, while the proportion of atypical sites for WEB implantation increased. WEB implantation was technically successful in 96.0%, and the ratio of WEB width to dome width increased during the study period, indicating oversizing. The neurological complication rate was 4.9% (1.5% major, 3.4% minor) and the mid-term complete occlusion rate was 60.6% (81.9% adequate occlusion), with no statistical differences in either outcome measure between the study periods. In multivariate analyses, the use of WEB 17 was associated with increased technical success (HR: 7.4, 95%CI: 2.4-23.6, p <0.01), whereas ruptured aneurysm status (HR: 2.5, 95%CI: 1.0-6.0, p =0.04) and the use of additional stents (HR: 4.8, 95%CI: 1.6-14.4, p <0.01) predicted thromboembolic complications. Appropriate oversizing of the WEB favored mid-term complete occlusion (HR: 10.5, 95%CI: 1.3-83.3, p =0.03). The results suggest an expansion of the indications for WEB implantation and highlight the importance of oversizing for treatment efficacy.
| Item Type: | Article |
| Creators: | Creators Email ORCID ORCID Put Code Liebig, Thomas UNSPECIFIED UNSPECIFIED UNSPECIFIED Siebert, Eberhard UNSPECIFIED UNSPECIFIED UNSPECIFIED Pflaeging, Muriel UNSPECIFIED UNSPECIFIED UNSPECIFIED Radomi, Alexandra UNSPECIFIED UNSPECIFIED UNSPECIFIED Dorn, Franziska UNSPECIFIED UNSPECIFIED UNSPECIFIED |
| URN: | urn:nbn:de:hbz:38-815882 |
| Identification Number: | 10.1038/s41598-024-75064-2 |
| Journal or Publication Title: | Scientific Reports |
| Volume: | 14 |
| Number: | 1 |
| Page Range: | pp. 1-11 |
| Date: | 16 October 2024 |
| Publisher: | Springer Nature |
| ISSN: | 2045-2322 |
| Language: | English |
| Faculty: | Faculty of Medicine |
| Divisions: | Faculty of Medicine > Radiologische Diagnostik > Institut und Poliklinik für Radiologische Diagnostik |
| Subjects: | Medical sciences Medicine |
| Uncontrolled Keywords: | Keywords Language Aneurysm occlusion ; Angiographic ; Flow-disruption ; Intrasaccular ; Stroke English |
| ['eprint_fieldname_oa_funders' not defined]: | Publikationsfonds UzK |
| Refereed: | Yes |
| URI: | http://kups.ub.uni-koeln.de/id/eprint/81588 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
![]() |
View Item |
https://orcid.org/0000-0002-2620-7611