Schmitz, Jan
ORCID: 0000-0003-0282-097X, Aeschbach, Daniel, Beccard, Inga, Frings, Nina, Hinkelbein, Jochen
ORCID: 0000-0003-3585-9459, Jordan, Jens, Kammerer, Tobias
ORCID: 0000-0001-8920-7187, Liebold, Felix, Limper, Ulrich
ORCID: 0000-0001-9927-4180, Post, Titiaan, Schick, Volker
ORCID: 0000-0002-2090-7836, Tank, Jens and Elmenhorst, Eva-Maria
(2024).
Chest compression quality decreases in hypoxic conditions simulating an airliner cabin at cruising altitude: a randomized, controlled, double-blind Manikin Study.
Scientific Reports, 14 (1).
pp. 1-9.
Springer Nature.
ISSN 2045-2322
|
PDF
s41598-024-77149-4.pdf Bereitstellung unter der CC-Lizenz: Creative Commons Attribution. Download (2MB) |
Abstract
[Artikel-Nr.: 25971] Air traveler numbers are predicted to reach 4.0 billion in 2024. Between 1/15,000–50,000 passengers will experience acute medical problems inflight with cardiac arrests requiring cardiopulmonary resuscitation (CPR) accounting for 0.3% of medical emergencies. Hypoxia in airplane cabins could impair oxygenation and physical performance of caregivers. We conducted a randomized controlled, double-blind study to test the hypothesis that hypoxia decreases the effectiveness in performing CPR. We randomized 24 healthcare professionals to two different study arms, each consisting of two conditions: arm (1) ‘hypoxia (FiO 2 15%, equivalent to 2400 m altitude)’ versus ‘normoxia’; arm (2) ‘hypoxia + supplemental oxygen’ versus ‘normoxia + supplemental oxygen’. The order of conditions was counterbalanced and a minimum wash-out period of 24 h was granted between conditions. In each condition participants performed a 5-min cardiac compression only CPR (CCO-CPR) using a full-body manikin after one, three and six hours in an altitude chamber. Mixed ANOVAs with post-hoc false-discovery-rate adjusted pairwise comparisons indicated that although compression frequency was maintained, the number of compressions with correct depth was decreased at all times during hypoxia compared to normoxia (all p < 0.002). After 6 h hypoxia exposure, mean compression depth was below the recommended compression depth defined by ERC/AHA guidelines and reduced compared to normoxia (42.4 ± 12.6 mm vs. 54.6 ± 4.3 mm, p < 0.0001). Supplemental oxygen during CCO-CPR in hypoxia prevented the decrease of compression-depth (55.3 ± 3 mm). Extended hypoxia exposure akin to conditions in airplane cabins can reduce quality of chest compressions during CPR. Supplemental oxygen for healthcare providers is an effective countermeasure.
| Item Type: | Article |
| Creators: | Creators Email ORCID ORCID Put Code Aeschbach, Daniel UNSPECIFIED UNSPECIFIED UNSPECIFIED Beccard, Inga UNSPECIFIED UNSPECIFIED UNSPECIFIED Frings, Nina UNSPECIFIED UNSPECIFIED UNSPECIFIED Jordan, Jens UNSPECIFIED UNSPECIFIED UNSPECIFIED Liebold, Felix UNSPECIFIED UNSPECIFIED UNSPECIFIED Post, Titiaan UNSPECIFIED UNSPECIFIED UNSPECIFIED Tank, Jens UNSPECIFIED UNSPECIFIED UNSPECIFIED Elmenhorst, Eva-Maria UNSPECIFIED UNSPECIFIED UNSPECIFIED |
| URN: | urn:nbn:de:hbz:38-815941 |
| Identification Number: | 10.1038/s41598-024-77149-4 |
| Journal or Publication Title: | Scientific Reports |
| Volume: | 14 |
| Number: | 1 |
| Page Range: | pp. 1-9 |
| Date: | 29 October 2024 |
| Publisher: | Springer Nature |
| ISSN: | 2045-2322 |
| Language: | English |
| Faculty: | Faculty of Medicine |
| Divisions: | Faculty of Medicine > Anästhesiologie und Operative Intensivmedizin > Klinik für Anästhesiologie und Operative Intensivmedizin |
| Subjects: | Medical sciences Medicine |
| Uncontrolled Keywords: | Keywords Language CPR ; Hypoxia, Manikin, In-flight medical emergency, Resuscitation English |
| ['eprint_fieldname_oa_funders' not defined]: | Publikationsfonds UzK |