Heimann, Julius ORCID: 0009-0000-8423-4928, Schramm, Thomas, Grauduszus, Martin and Joisten, Christine ORCID: 0000-0002-2455-8901 (2025). Examining the Effects of Different Exertion Levels and Reference Standards on the Diagnostic Accuracy of Exercise ECG for Detecting Coronary Artery Disease — A Pilot Study. Annals of Noninvasive Electrocardiology, 30 (1). pp. 1-11. Wiley. ISSN 1082-720X

[thumbnail of Noninvasive Electrocardiol - 2024 - Heimann - Examining the Effects of Different Exertion Levels and Reference Standards on.pdf] PDF
Noninvasive Electrocardiol - 2024 - Heimann - Examining the Effects of Different Exertion Levels and Reference Standards on.pdf
Bereitstellung unter der CC-Lizenz: Creative Commons Attribution Non-commercial.

Download (638kB)
Identification Number:10.1111/anec.70042

Abstract

[Artikel-Nr.: e70042] Background: Exercise electrocardiogram (ECG) is frequently used for evaluating patients with suspected coronary artery dis- ease (CAD). However, it has been downgraded in international guidelines due to a limited sensitivity and specificity, compared with other non-invasive tests. Methods: We hypothesized, that a sufficient exertion going beyond 85% of the age predicted maximal heart rate (APMHR), by considering the achieved level of workload can improve sensitivity and specificity of the exercise ECG. Secondly, the performance of exercise ECG, when evaluated against a functional reference standard has barely been investigated, although an improved diagnostic accuracy has been reported for other non-invasive tests in this case. Therefore, in this pilot study, a total of 147 pa- tients without known CAD who underwent exercise ECG followed by coronary angiography within 90 days were retrospectively evaluated. Results: The combined end point of 85% of APMHR and 75% of the predicted workload showed a slight but not statistically sig- nificant benefit over APMHR alone (66.7% vs. 58.1%; p = 0.545). The sensitivity of ST-segment depression was 51.3% for detecting anatomically defined CAD and 62.5% for functionally relevant CAD (p = 0.378). Conclusions: Although the results of this pilot study lack statistical significance, the numeric differences clearly justify further research on this topic.

Item Type: Article
Creators:
Creators
Email
ORCID
ORCID Put Code
Heimann, Julius
UNSPECIFIED
UNSPECIFIED
Schramm, Thomas
UNSPECIFIED
UNSPECIFIED
UNSPECIFIED
Grauduszus, Martin
UNSPECIFIED
UNSPECIFIED
UNSPECIFIED
Joisten, Christine
UNSPECIFIED
UNSPECIFIED
URN: urn:nbn:de:hbz:38-816583
Identification Number: 10.1111/anec.70042
Journal or Publication Title: Annals of Noninvasive Electrocardiology
Volume: 30
Number: 1
Page Range: pp. 1-11
Number of Pages: 11
Date: 20 January 2025
Publisher: Wiley
ISSN: 1082-720X
Language: English
Faculty: Faculty of Medicine
Divisions: Faculty of Medicine > Allgemeinmedizin
Subjects: Medical sciences Medicine
Uncontrolled Keywords:
Keywords
Language
coronary artery disease ; diagnostic accuracy ; exercise ECG ; exertion ; reference standard
English
['eprint_fieldname_oa_funders' not defined]: Publikationsfonds UzK
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/81658

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item