Rausch, Valentin, Wegmann, Sebastian, Hackl, Michael, Leschinger, Tim, Neiss, Wolfram F., Scaal, Martin, Mueller, Lars P. and Wegmann, Kilian (2019). The radial head size in relation to osseous landmarks of the forearm. Surg. Radiol. Anat., 41 (4). S. 415 - 422. PARIS: SPRINGER FRANCE. ISSN 1279-8517

Full text not available from this repository.

Abstract

PurposeRadial head fractures are regularly treated with radial head arthroplasty. To prevent limited motion or pain, the implant's size should match its normal anatomy. Preoperative estimation of the radial head size helps in finding the correct head component. The aim of this study was to measure bony landmarks in proximity to the radial head to estimate the required size of a prosthesis preoperatively.MethodsAnatomical landmarks on 82 elbows from 41 embalmed specimens (19 male, 22 female) were measured using a digital caliper after removal of the specimens' tissue: the largest and smallest radial head diameter, length of the radius (styloid tip to radial head articular surface), and the length of the ulna (styloid tip to coronoid base). Additionally, cranio-caudal and antero-posterior diameters of the capitulum on scaled lateral elbow X-ray images were measured.ResultsThe mean largest and smallest radial head diameters were 24.2mm (2.2, range 19.9-30.3; ICC=0.992) and 22.5mm (+/- 2.0, range 18.9-27.5; ICC=0.985). The mean radius length was 23.8cm (+/- 1.6, range 20.1-27.1; ICC=0.986), and the mean ulna length was 23.1cm (+/- 1.6, range 19.3-26.3; ICC=0.969). The mean antero-posterior capitulum diameter was 16.2mm (+/- 2.4, range 10.4-21.0; ICC=0.506), and the mean cranio-caudal diameter was 17.0mm (+/- 3.3, range 10.0-23.9; ICC=0.529). The highest correlation to radial head diameters could be shown for diameters of the contralateral radial head and the radius length.Conclusions For preoperative estimation of the radial head, the diameters of the contralateral radial head or the radius length are the most accurate.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Rausch, ValentinUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Wegmann, SebastianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Hackl, MichaelUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Leschinger, TimUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Neiss, Wolfram F.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Scaal, MartinUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Mueller, Lars P.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Wegmann, KilianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-153045
DOI: 10.1007/s00276-018-2160-8
Journal or Publication Title: Surg. Radiol. Anat.
Volume: 41
Number: 4
Page Range: S. 415 - 422
Date: 2019
Publisher: SPRINGER FRANCE
Place of Publication: PARIS
ISSN: 1279-8517
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
PROSTHETIC DESIGN; IMPLANT; ARTHROPLASTY; MORPHOLOGY; STABILITY; DIAMETERMultiple languages
Anatomy & Morphology; Radiology, Nuclear Medicine & Medical Imaging; SurgeryMultiple languages
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/15304

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item