Dreiseidler, Timo, Lentzen, Max-Philipp, Zirk, Matthias, Safi, Ali-Farid, Zoeller, Joachim E. and Kreppel, Matthias (2017). Systematic three-dimensional analysis of wafer-based maxillary repositioning procedures in orthognathic surgery. J. Cranio-MaxilloFac. Surg., 45 (11). S. 1828 - 1835. EDINBURGH: CHURCHILL LIVINGSTONE. ISSN 1878-4119

Full text not available from this repository.

Abstract

Purpose: Little is known about the three-dimensional (3D) transfer accuracy in maxillary repositioning procedures based on conventionally manufactured dental-mounted wafers. The purpose of the present study was a systematic 3D analysis for wafer-based maxillary positioning in orthognathic surgery. Materials and methods: A total of 92 patients underwent Le Fort I in addition to mandibular bilateral sagittal split osteotomies (BSSO). Alignment of the pre-and postsurgical CBCT data sets allowed measuring maxillary position changes in axial, sagittal and transversal directions. Results: The highest achieved absolute transfer inaccuracies were 1.37 mm, +/- 0.84 in the sagittal direction, followed by 1.15 mm, +/- 0.69 in the axial, as well as 1.05 mm, +/- 0.79 in the transversal direction. The largest relative deviations could be found for repositions in the transversal plane (109.4%, +/- 4.5), followed by the axial (66.2%, +/- 51.5) and sagittal plane (49.3%, +/- 2.2). Significant transfer accuracy differences of repositioning procedures in the sagittal direction, mainly advancement procedures, could be detected if performed with (1.75 mm, +/- 0.90) or without (1.18 mm, +/- 0.78) additional rotational correction component. No significant differences were found between unidirectional and multidirectional maxillary correction procedures. Conclusion: The present study for the first time delivers systematic 3D accuracy data of wafer-based maxillary positioning procedures, attesting to its feasibility but also further encouraging the search for improvement strategies. (C) 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Dreiseidler, TimoUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Lentzen, Max-PhilippUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Zirk, MatthiasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Safi, Ali-FaridUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Zoeller, Joachim E.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Kreppel, MatthiasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-212020
DOI: 10.1016/j.jcms.2017.08.022
Journal or Publication Title: J. Cranio-MaxilloFac. Surg.
Volume: 45
Number: 11
Page Range: S. 1828 - 1835
Date: 2017
Publisher: CHURCHILL LIVINGSTONE
Place of Publication: EDINBURGH
ISSN: 1878-4119
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
BEAM COMPUTED-TOMOGRAPHY; ACCURACY; SUPERIMPOSITION; MODELS; ORTHODONTICS; SIMULATION; OSTEOTOMY; CTMultiple languages