Herren, Christian, Beckmann, Agnes, Meyer, Sabine, Pishnamaz, Miguel, Mundt, Marion, Sobottke, Rolf, Prescher, Andreas, Stoffel, Marcus, Markert, Bernd ORCID: 0000-0001-7893-6229, Kobbe, Philipp, Pape, Hans-Christoph, Eysel, Peer and Siewe, Jan (2017). Biomechanical testing of a PEEK-based dynamic instrumentation device in a lumbar spine model. Clin. Biomech., 44. S. 67 - 75. OXFORD: ELSEVIER SCI LTD. ISSN 1879-1271

Full text not available from this repository.

Abstract

Background: The purpose of this study was to investigate the range-of-motion after posterior polyetheretherketone-based rod stabilisation combined with a dynamic silicone hinge in order to compare it with titanium rigid stabilisation. Methods: Five human cadaveric lumbar spines with four vertebra each (L2 to L5) were tested in a temperature adjustable spine-testing set-up in four trials: (1) native measurement; (2) kinematics after rigid monosegmental titanium rod instrumentation with anterior intervertebral bracing of the segment L4/5; (3) kinematics after hybrid posterior polyetheretherketone rod instrumentation combined with a silicone hinge within the adjacent level (L3/4) and (4) kinematics after additional decompression with laminectomy of L4 and bilateral resection of the inferior articular processes (L3). During all steps, the specimens were loaded quasi-statically with 1 degrees/s with pure moment up to 7.5 Nm in flexion/extension, lateral bending and axial rotation. Findings: In comparison to the native cadaveric spine, both the titanium device and polyetheretherketone-based device reduce the range-of-motion within the level L4/5 significantly (flexion/extension: reduction of 77%, p < 0.001; lateral bending: reduction of 62%, p < 0.001; axial rotation: reduction of 71%, p < 0.001). There was a clear stabilisation effect after hybrid-instrumentation within the level L3/4, especially in flexion/extension (64%, p < 0.001) and lateral bending (62%, p < 0.001) but without any effect on the axial rotation. Any temperature dependency has not been observed. Interpretation: Surprisingly, the hybrid device compensates for laminectomy L4 and destabilising procedure within the level L3/4 in comparison to other implants. Further studies must be performed to show its effectiveness regarding the adjacent segment instability. (C) 2017 Elsevier Ltd. All rights reserved.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Herren, ChristianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Beckmann, AgnesUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Meyer, SabineUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Pishnamaz, MiguelUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Mundt, MarionUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Sobottke, RolfUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Prescher, AndreasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Stoffel, MarcusUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Markert, BerndUNSPECIFIEDorcid.org/0000-0001-7893-6229UNSPECIFIED
Kobbe, PhilippUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Pape, Hans-ChristophUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Eysel, PeerUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Siewe, JanUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-232239
DOI: 10.1016/j.clinbiomech.2017.03.009
Journal or Publication Title: Clin. Biomech.
Volume: 44
Page Range: S. 67 - 75
Date: 2017
Publisher: ELSEVIER SCI LTD
Place of Publication: OXFORD
ISSN: 1879-1271
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
IN-VITRO; DISC DEGENERATION; STABILIZATION; FUSION; MOTION; SYSTEM; RANGEMultiple languages
Engineering, Biomedical; Orthopedics; Sport SciencesMultiple languages
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/23223