Suchsland, Juliane, Winter, Theresa, Greiser, Anne, Streichert, Thomas, Otto, Benjamin, Mayerle, Julia ORCID: 0000-0002-3666-6459, Runge, Soeren, Kallner, Anders, Nauck, Matthias and Petersmann, Astrid (2017). Extending laboratory automation to the wards: effect of an innovative pneumatic tube system on diagnostic samples and transport time. Clin. Chem. Lab. Med., 55 (2). S. 225 - 231. BERLIN: WALTER DE GRUYTER GMBH. ISSN 1437-4331

Full text not available from this repository.

Abstract

Background: The innovative pneumatic tube system (iPTS) transports one sample at a time without the use of cartridges and allows rapid sending of samples directly into the bulk loader of a laboratory automation system (LAS). We investigated effects of the iPTS on samples and turn-around time (TAT). Methods: During transport, a mini data logger recorded the accelerations in three dimensions and reported them in arbitrary area under the curve (AUC) units. In addition representative quantities of clinical chemistry, hematology and coagulation were measured and compared in 20 blood sample pairs transported by iPTS and courier. Results: Samples transported by iPTS were brought to the laboratory (300 m) within 30 s without adverse effects on the samples. The information retrieved from the data logger showed a median AUC of 7 and 310 arbitrary units for courier and iPTS transport, respectively. This is considerably below the reported limit for noticeable hemolysis of 500 arbitrary units. Conclusions: iPTS reduces TAT by reducing the hands-on time and a fast transport. No differences in the measurement results were found for any of the investigated 36 analytes between courier and iPTS transport. Based on these findings the iPTS was cleared for clinical use in our hospital.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Suchsland, JulianeUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Winter, TheresaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Greiser, AnneUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Streichert, ThomasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Otto, BenjaminUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Mayerle, JuliaUNSPECIFIEDorcid.org/0000-0002-3666-6459UNSPECIFIED
Runge, SoerenUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Kallner, AndersUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Nauck, MatthiasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Petersmann, AstridUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-241573
DOI: 10.1515/cclm-2016-0380
Journal or Publication Title: Clin. Chem. Lab. Med.
Volume: 55
Number: 2
Page Range: S. 225 - 231
Date: 2017
Publisher: WALTER DE GRUYTER GMBH
Place of Publication: BERLIN
ISSN: 1437-4331
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
INCREASED HEMOLYSIS; DELIVERY-SYSTEM; INTERFERENCEMultiple languages
Medical Laboratory TechnologyMultiple languages
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/24157

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item