Hokamp, Nils Grosse, Eck, Brendan, Siedek, Florian, dos Santos, Daniel Pinto, Holz, Jasmin A., Maintz, David and Haneder, Stefan (2020). Quantification of metal artifacts in computed tomography: methodological considerations. Quant. Imaging Med. Surg., 10 (5). S. 1033 - 1045. SHATIN: AME PUBL CO. ISSN 2223-4306

Full text not available from this repository.

Abstract

Numerous methods for artifact quantification in computed tomography (CT) imaging have been suggested. This study evaluated their utility with regards to correspondence with visual artifact perception and reproducibility. Two titanium rods (5 and 10 mm) were examined with 25 different scanning- and imagereconstruction parameters resulting in different types and extents of artifacts. Four radiologists evaluated every image against each other using an in-house developed software. Rating was repeated two times (2,400 comparisons = 2 times x 4 readers x 300 comparisons). Rankings were combined to obtain a reference ranking. Proposed approaches for artifact quantification include manual measurement of attenuation, standard deviation and noise and sophisticated algorithm-based approaches within the image- and frequencydomain. Two radiologists conducted manual measurements twice while the aforementioned algorithms were implemented within the Matlab-Environment allowing for automated image analysis. The reference ranking was compared to all aforementioned methods for artifact quantification to identify suited approaches. Besides visual analysis, Kappa-statistics and intraclass correlation coefficients (ICC) were used. Intra- and Interreader agreements of visual artifact perception were excellent (ICC 0.85-0.92). No quantitative method was able to represent the exact ranking of visually perceived artifacts; however, ICC for manual measurements were low (ICC 0.25-0.97). The method that showed best correspondence and reproducibility used a Fouriertransformed linear ROI and lower-end frequency bins. Automated measurements of artifact extent should be preferred over manual measurements as the latter show a limited reproducibility. One method that allows for automated quantification of such artefacts is made available as an electronic supplement.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Hokamp, Nils GrosseUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Eck, BrendanUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Siedek, FlorianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
dos Santos, Daniel PintoUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Holz, Jasmin A.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Maintz, DavidUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Haneder, StefanUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-335456
DOI: 10.21037/qims.2020.04.03
Journal or Publication Title: Quant. Imaging Med. Surg.
Volume: 10
Number: 5
Page Range: S. 1033 - 1045
Date: 2020
Publisher: AME PUBL CO
Place of Publication: SHATIN
ISSN: 2223-4306
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
DUAL-ENERGY CT; ORTHOPEDIC HARDWARE; REDUCTION; SPINEMultiple languages
Radiology, Nuclear Medicine & Medical ImagingMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/33545

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item