Van Hedent, Steven, Tatsuoka, Curtis, Carr, Sarah ORCID: 0000-0001-6641-4415, Laukamp, Kai Roman, Eck, Brendan, Hokamp, Nils Grosse, Kessner, Rivka, Ros, Pablo and Jordan, David (2020). Impact of Patient Size and Radiation Dose on Accuracy and Precision of Iodine Quantification and Virtual Noncontrast Values in Dual-layer Detector CT-A Phantom Study. Acad. Radiol., 27 (3). S. 409 - 421. NEW YORK: ELSEVIER SCIENCE INC. ISSN 1878-4046
Full text not available from this repository.Abstract
Rationale and Objectives: Iodine quantification (IQ) and virtual noncontrast (VNC) images produced by dual-energy CT (DECT) can be used for various clinical applications. We investigate the performance of dual-layer DECT (DLDECT) in different phantom sizes and varying radiation doses and tube voltages, including a low-dose pediatric setting. Materials and Methods: Three phantom sizes (simulating a 10-year-old child, an average, and a large-sized adult) were scanned with iodine solution inserts with concentrations ranging 0-32 mg/ml, using the DLDECT. Each phantom size was scanned with CTDIvol 2-15 mGy at 120 and 140 kVp. The smallest phantom underwent additional scans with CTDIvol 0.9-1.8 mGy. All scans were repeated 3 times. Each iodine insert was analyzed using VNC and IQ images for accuracy and precision, by comparison to known values. Results: For scans from 2 to 15 mGy mean VNC attenuation and IQ error in the iodine inserts in the small, medium, and large phantoms was 1.2 HU +/- 3.2, -1.2 HU +/- 14.9, 2.6 HU +/- 23.6; and +0.1 mg/cc +/- 0.4, -0.9 mg/cc +/- 0.9, and -1.8 mg/cc +/- 1.8, respectively. In this dose range, there were no significant differences (p >= 0.05) in mean VNC attenuation or IQ accuracy in each phantom size, while IQ was significantly less precise in the small phantom at 2 mGy and 10 mGy (p < 0.05). Scans with CTDIvol 0.9-1.8 mGy in the small phantom showed a limited, but statistically significantly lower VNC attenuation precision and IQ accuracy (-0.5 HU +/- 5.3 and -0.3 mg/cc +/- 0.5, respectively) compared to higher dose scans in the same phantom size. Conclusion: Performance of iodine quantification and subtraction by VNC images in DLDECT is largely dose independent, with the primary factor being patient size. Low-dose pediatric scan protocols have a significant, but limited impact on IQ and VNC attenuation values.
Item Type: | Journal Article | ||||||||||||||||||||||||||||||||||||||||
Creators: |
|
||||||||||||||||||||||||||||||||||||||||
URN: | urn:nbn:de:hbz:38-342992 | ||||||||||||||||||||||||||||||||||||||||
DOI: | 10.1016/j.acra.2019.02.013 | ||||||||||||||||||||||||||||||||||||||||
Journal or Publication Title: | Acad. Radiol. | ||||||||||||||||||||||||||||||||||||||||
Volume: | 27 | ||||||||||||||||||||||||||||||||||||||||
Number: | 3 | ||||||||||||||||||||||||||||||||||||||||
Page Range: | S. 409 - 421 | ||||||||||||||||||||||||||||||||||||||||
Date: | 2020 | ||||||||||||||||||||||||||||||||||||||||
Publisher: | ELSEVIER SCIENCE INC | ||||||||||||||||||||||||||||||||||||||||
Place of Publication: | NEW YORK | ||||||||||||||||||||||||||||||||||||||||
ISSN: | 1878-4046 | ||||||||||||||||||||||||||||||||||||||||
Language: | English | ||||||||||||||||||||||||||||||||||||||||
Faculty: | Unspecified | ||||||||||||||||||||||||||||||||||||||||
Divisions: | Unspecified | ||||||||||||||||||||||||||||||||||||||||
Subjects: | no entry | ||||||||||||||||||||||||||||||||||||||||
Uncontrolled Keywords: |
|
||||||||||||||||||||||||||||||||||||||||
URI: | http://kups.ub.uni-koeln.de/id/eprint/34299 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
View Item |