Hickethier, Tilman, Kroeger, Jan Robert, Lennartz, Simon, Doerner, Jonas, Maintz, David and Chang, De-Hua (2020). Venous-phase chest CT with reduced contrast medium dose: Utilization of spectral low keV monoenergetic images improves image quality. Eur. J. Radiol., 122. CLARE: ELSEVIER IRELAND LTD. ISSN 1872-7727

Full text not available from this repository.

Abstract

Purpose: Intravenous contrast administration is crucial in many CT examinations but also poses a potential risk to the patient. Monoenergetic images (MonoE) of dual-energy CT systems can virtually increase iodine attenuation and might improve image quality (IQ) if contrast dose is reduced. In this study, we investigated the influence of MonoE on lymph node (LN) delineation and IQ in chest CT examinations with significantly reduced contrast dose (50 %) of a novel dual-layer CT (DLCT). Method: 30 patients with clinically indicated reduced contrast dose underwent venous-phase chest DLCT scans. Conventional polyenergetic (PolyE) and MonoE images at 40 keV were calculated. The contrast difference of hilar lymph nodes (LN-CD) to the adjacent right pulmonary artery, their signal-to-noise (SNR) and contrast-tonoise-ratio (CNR) were determined. Subjective IQ was evaluated by 2 readers with respect to LN delineation and overall contrast enhancement (CE) using a 5-point-Likert-scale. Results: LN-CD, SNR and CNR were significantly higher in MonoE than in PolyE images (LN-CD 92.3 +/- 37.9 vs. 33.1 +/- 14.5 HU, SNR 8.4 +/- 3.4 vs. 4.0 +/- 1.2, CNR 9.2 +/- 6.3 vs. 2.6 +/- 1.5; all p < 0.01). The LN delineation (3.7 +/- 0.9 vs.1.8 +/- 0.7; p < 0.01) and the CE (3.9 +/- 0.7 vs. 2.3 +/- 0.7; p < 0.01) were rated significantly better for MonoE than for PolyE images. There was no MonoE examination classified as non-diagnostic. Conclusions: Subjective and objective IQ parameters can be significantly improved for venous-phase chest CT examinations with reduced contrast doses by utilization of low-keV MonoE reconstructions. All MonoE images provided sufficient overall CE and therefore reduced contrast doses might be considered in a wider range of DLCT examinations and patients.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Hickethier, TilmanUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Kroeger, Jan RobertUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Lennartz, SimonUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Doerner, JonasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Maintz, DavidUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Chang, De-HuaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-352405
DOI: 10.1016/j.ejrad.2019.108756
Journal or Publication Title: Eur. J. Radiol.
Volume: 122
Date: 2020
Publisher: ELSEVIER IRELAND LTD
Place of Publication: CLARE
ISSN: 1872-7727
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
HEPATOCELLULAR-CARCINOMA; TUBE VOLTAGE; REDUCTION; RISK; PROTOCOLS; LYMPHOMA; DISEASE; KVP; PETMultiple languages
Radiology, Nuclear Medicine & Medical ImagingMultiple languages