Madershahian, Navid, Scherner, Maximilian, Mueller-Ehmsen, Jochen, Halbach, Marcel, Hickethier, Tilman ORCID: 0000-0001-9303-9470, Velden, Ralf, Choi, Yeong-Hoon, Wippermann, Jens and Wahlers, Thorsten (2014). Baroreflex activation therapy in patients with pre-existing implantable cardioverter-defibrillator: compatible, complementary therapies. Europace, 16 (6). S. 861 - 866. OXFORD: OXFORD UNIV PRESS. ISSN 1532-2092

Full text not available from this repository.

Abstract

The Neo (TM) System (CVRx) is an implantable device, CE certified for the treatment of resistant hypertension and investigationally used to treat systolic heart failure by electrical stimulation of the carotid baroreceptors. It is unknown whether interaction might exist between the Neo System and implantable cardioverter-defibrillators (ICDs). Compatibility of the Neo device was tested in seven consecutive patients with pre-existing ICDs. Intra- and post-operative testing was completed with ICD and Neo settings programmed to provoke interaction. Intracardiac electrograms were printed to determine interaction with the ICD. Interaction testing during implantation and follow-up showed that there was no device-device interaction. No interaction was observed at maximum atrial and ventricular sensitivity settings and maximum Neo output settings. Combined therapy with the Neo device and at least in this study reported that transvenous ICD systems can be performed safely.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Madershahian, NavidUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Scherner, MaximilianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Mueller-Ehmsen, JochenUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Halbach, MarcelUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Hickethier, TilmanUNSPECIFIEDorcid.org/0000-0001-9303-9470UNSPECIFIED
Velden, RalfUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Choi, Yeong-HoonUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Wippermann, JensUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Wahlers, ThorstenUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-436919
DOI: 10.1093/europace/eut403
Journal or Publication Title: Europace
Volume: 16
Number: 6
Page Range: S. 861 - 866
Date: 2014
Publisher: OXFORD UNIV PRESS
Place of Publication: OXFORD
ISSN: 1532-2092
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
HEART-FAILURE; BARORECEPTOR STIMULATION; BLOOD-PRESSURE; HYPERTENSIONMultiple languages
Cardiac & Cardiovascular SystemsMultiple languages