Kaufmann, Jost ORCID: 0000-0002-5289-6465, Laschat, Michael, Hellmich, Martin ORCID: 0000-0001-5174-928X and Wappler, Frank (2013). A randomized controlled comparison of the Bonfils fiberscope and the GlideScope Cobalt AVL video laryngoscope for visualization of the larynx and intubation of the trachea in infants and small children with normal airways. Pediatr. Anesth., 23 (10). S. 913 - 920. HOBOKEN: WILEY. ISSN 1460-9592

Full text not available from this repository.

Abstract

Background: The Bonfils fiberscope (BF) used without the assistance of a laryngoscope failed to improve the view of direct laryngoscopy in children with normal airways. We hypothesized that if BF is supported by a laryngoscope- as recommended by its inventor-it can provide comparably good visualization of the glottis as the GlideScope (R) Cobalt AVL video laryngoscope (GS). Methods: We included 100 children with normal airways in a randomized controlled trial. The study consisted of assessing the airway by direct laryngoscopy (DL), followed by intubation using either the BF or the GlideScope. Main outcome measures were the quality of visualization of the larynx by the percentage of glottis opening seen (POGO) and the time needed for intubation of the trachea. Results: Visualization of the larynx (POGO) using the BF was significantly better than with DL (P = 0.016) or with GS (P = 0.001). The DL provided an allover better visualization than GS, although this difference was not significant and solely attributable to children weighing <15 kg. Intubation was successful in all cases with both devices. The time needed for intubation was shorter using the BF (36 +/- 8 s) than with the GlideScope (49 +/- 12 s, P < 0.001). Conclusion: The Bonfils fiberscope significantly improved the view on the larynx compared with direct

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Kaufmann, JostUNSPECIFIEDorcid.org/0000-0002-5289-6465UNSPECIFIED
Laschat, MichaelUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Hellmich, MartinUNSPECIFIEDorcid.org/0000-0001-5174-928XUNSPECIFIED
Wappler, FrankUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-475213
DOI: 10.1111/pan.12137
Journal or Publication Title: Pediatr. Anesth.
Volume: 23
Number: 10
Page Range: S. 913 - 920
Date: 2013
Publisher: WILEY
Place of Publication: HOBOKEN
ISSN: 1460-9592
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
STANDARD DIRECT LARYNGOSCOPY; PEDIATRIC AIRWAY; CLINICAL-TRIALMultiple languages
Anesthesiology; PediatricsMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/47521

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item