Lentzsch, Anna, Schoellhorn, Laura, Schnorr, Christel, Siggel, Robert and Liakopoulos, Sandra (2022). Comparison of swept-source versus spectral-domain optical coherence tomography angiography for detection of macular neovascularization. Graefes Arch. Clin. Exp. Ophthalmol., 260 (1). S. 113 - 120. NEW YORK: SPRINGER. ISSN 1435-702X

Full text not available from this repository.

Abstract

Purpose To compare swept-source (SS) versus spectral-domain (SD) optical coherence tomography angiography (OCTA) for the detection of macular neovascularization (MNV). Methods In this prospective cohort study, 72 eyes of 54 patients with subretinal hyperreflective material (SHRM) and/or pigment epithelial detachment (PED) on OCT possibly corresponding to MNV in at least one eye were included. OCTA scans were acquired using two devices, the PLEX Elite 9000 SS-OCTA and the Spectralis SD-OCTA. Fluorescein angiography (FA) was used as reference. Two graders independently evaluated en face OCTA images using a preset slab as well as a manually modified slab, followed by a combination of en face and cross-sectional OCTA. Results Sensitivity (specificity) for the automated slabs was 51.7% (93.0%) for SS-OCTA versus 58.6% (95.3%) for SD-OCTA. Manual modification of segmentation increased sensitivity to 79.3% for SS-OCTA but not for SD-OCTA (58.6%). The combination of en face OCTA with cross-sectional OCTA reached highest sensitivity values (SS-OCTA: 82.8%, SD-OCTA: 86.2%), and lowest number of cases with discrepancies between SS-OCTA and SD-OCTA (4.2%). Fleiss kappa as measure of concordance between FA, SS-OCTA, and SD-OCTA was 0.56 for the automated slabs, 0.60 for the manual slabs, and 0.73 (good agreement) for the combination of en face OCTA with cross-sectional OCTA. Concordance to FA was moderate for the automated slabs and good for manual slabs and combination with cross-sectional OCTA of both devices. Conclusion Both devices reached comparable results regarding the detection of MNV on OCTA. Sensitivity for MNV detection and agreement between devices was best when evaluating a combination of en face and cross-sectional OCTA.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Lentzsch, AnnaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Schoellhorn, LauraUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Schnorr, ChristelUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Siggel, RobertUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Liakopoulos, SandraUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-583716
DOI: 10.1007/s00417-021-05229-6
Journal or Publication Title: Graefes Arch. Clin. Exp. Ophthalmol.
Volume: 260
Number: 1
Page Range: S. 113 - 120
Date: 2022
Publisher: SPRINGER
Place of Publication: NEW YORK
ISSN: 1435-702X
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
OCT-ANGIOGRAPHY; CHOROIDAL NEOVASCULARIZATION; IMAGE ARTIFACTS; QUANTITATIONMultiple languages
OphthalmologyMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/58371

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item