Goertz, Lukas, Liebig, Thomas, Siebert, Eberhard ORCID: 0000-0001-7395-6546, Pflaeging, Muriel, Forbrig, Robert, Pennig, Lenhard, Schlamann, Marc, Dorn, Franziska and Kabbasch, Christoph ORCID: 0000-0003-3712-2258 (2021). Intrasaccular Flow Disruption with the Woven EndoBridge for Narrow-Necked Aneurysms: A Safety and Feasibility Study. World Neurosurg., 151. S. E278 - 8. NEW YORK: ELSEVIER SCIENCE INC. ISSN 1878-8769
Full text not available from this repository.Abstract
OBJECTIVE: The Woven EndoBridge (WEB) received U.S. Food and Drug Administration approval for endovascular treatment of wide-necked bifurcation aneurysms. We evaluated the feasibility, safety, and efficacy of the WEB for treatment of narrow-necked aneurysms. METHODS: This multicenter study included 17 narrow necked aneurysms, defined by a neck width <4 mm and a dome-to-neck ratio >2. Aneurysm characteristics, treatment strategies, technical success, complications, and angiographic outcomes were retrospectively assessed. RESULTS: Aneurysm locations included the internal carotid artery (7 cases), anterior communicating artery (4 cases), middle cerebral artery (4 cases), and basilar artery (2 cases). The median aneurysm size was 7.4 mm with a median neck width of 2.3 mm. The technical success rate was 100%. There were no neurological complications. Angiographic control revealed complete and adequate occlusion in 13 of 15 (86.7%) and 14 of 15 (93.3%) cases, respectively, after 6 months and in 6 of 7 (85.6%) and 7 of 7 (100%) cases, respectively, after a median of 13 months. Two aneurysms were retreated with flow diverters. CONCLUSIONS: WEB embolization of narrow-necked aneurysms was technically feasible and safe and might be considered as an alternative treatment option to conventional coiling in selected cases. - RESULTS: Aneurysm locations included the internal carotid artery (7 cases), anterior communicating artery (4 cases), middle cerebral artery (4 cases), and basilar artery (2 cases). The median aneurysm size was 7.4 mm with a median neck width of 2.3 mm. The technical success rate was 100%. There were no neurological complications. Angiographic control revealed complete and adequate occlusion in 13 of 15 (86.7%) and 14 of 15 (93.3%) cases, respectively, after 6 months and in 6 of 7 (85.6%) and 7 of 7 (100%) cases, respectively, after a median of 13 months. Two aneurysms were retreated with flow diverters.
Item Type: | Journal Article | ||||||||||||||||||||||||||||||||||||||||
Creators: |
|
||||||||||||||||||||||||||||||||||||||||
URN: | urn:nbn:de:hbz:38-590374 | ||||||||||||||||||||||||||||||||||||||||
DOI: | 10.1016/j.wneu.2021.04.018 | ||||||||||||||||||||||||||||||||||||||||
Journal or Publication Title: | World Neurosurg. | ||||||||||||||||||||||||||||||||||||||||
Volume: | 151 | ||||||||||||||||||||||||||||||||||||||||
Page Range: | S. E278 - 8 | ||||||||||||||||||||||||||||||||||||||||
Date: | 2021 | ||||||||||||||||||||||||||||||||||||||||
Publisher: | ELSEVIER SCIENCE INC | ||||||||||||||||||||||||||||||||||||||||
Place of Publication: | NEW YORK | ||||||||||||||||||||||||||||||||||||||||
ISSN: | 1878-8769 | ||||||||||||||||||||||||||||||||||||||||
Language: | English | ||||||||||||||||||||||||||||||||||||||||
Faculty: | Unspecified | ||||||||||||||||||||||||||||||||||||||||
Divisions: | Unspecified | ||||||||||||||||||||||||||||||||||||||||
Subjects: | no entry | ||||||||||||||||||||||||||||||||||||||||
Uncontrolled Keywords: |
|
||||||||||||||||||||||||||||||||||||||||
URI: | http://kups.ub.uni-koeln.de/id/eprint/59037 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
View Item |