Pennig, Lenhard, Zopfs, David, Gertz, Roman, Bremm, Johannes, Zaeske, Charlotte, Hokamp, Nils Grosse, Celik, Erkan, Goertz, Lukas, Langenbach, Marcel, Persigehl, Thorsten, Gupta, Amit ORCID: 0000-0001-5345-6763, Borggrefe, Jan ORCID: 0000-0003-2908-7560, Lennartz, Simon and Laukamp, Kai Roman (2021). Reduction of CT artifacts from cardiac implantable electronic devices using a combination of virtual monoenergetic images and post-processing algorithms. Eur. Radiol., 31 (9). S. 7151 - 7162. NEW YORK: SPRINGER. ISSN 1432-1084
Full text not available from this repository.Abstract
Objectives To evaluate the reduction of artifacts from cardiac implantable electronic devices (CIEDs) by virtual monoenergetic images (VMI), metal artifact reduction (MAR) algorithms, and their combination (VMIMAR) derived from spectral detector CT (SDCT) of the chest compared to conventional CT images (CI). Methods In this retrospective study, we included 34 patients (mean age 74.6 +/- 8.6 years), who underwent a SDCT of the chest and had a CIED in place. CI, MAR, VMI, and VMIMAR (10 keV increment, range: 100-200 keV) were reconstructed. Mean and standard deviation of attenuation (HU) among hypo- and hyperdense artifacts adjacent to CIED generator and leads were determined using ROIs. Two radiologists qualitatively evaluated artifact reduction and diagnostic assessment of adjacent tissue. Results Compared to CI, MAR and VMIMAR >= 100 keV significantly increased attenuation in hypodense and significantly decreased attenuation in hyperdense artifacts at CIED generator and leads (p < 0.05). VMI >= 100 keV alone only significantly decreased hyperdense artifacts at the generator (p < 0.05). Qualitatively, VMI >= 100 keV, MAR, and VMIMAR >= 100 keV provided significant reduction of hyper- and hypodense artifacts resulting from the generator and improved diagnostic assessment of surrounding structures (p < 0.05). Diagnostic assessment of structures adjoining to the leads was only improved by MAR and VMIMAR 100 keV (p < 0.05), whereas keV values >= 140 with and without MAR significantly worsened diagnostic assessment (p < 0.05). Conclusions The combination of VMI and MAR as well as MAR as a standalone approach provides effective reduction of artifacts from CIEDs. Still, higher keV values should be applied with caution due to a loss of soft tissue and vessel contrast along the leads.
Item Type: | Journal Article | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Creators: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
URN: | urn:nbn:de:hbz:38-595296 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DOI: | 10.1007/s00330-021-07746-8 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Journal or Publication Title: | Eur. Radiol. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Volume: | 31 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Number: | 9 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Page Range: | S. 7151 - 7162 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Date: | 2021 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Publisher: | SPRINGER | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Place of Publication: | NEW YORK | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ISSN: | 1432-1084 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Language: | English | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Faculty: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Divisions: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Subjects: | no entry | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Uncontrolled Keywords: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
URI: | http://kups.ub.uni-koeln.de/id/eprint/59529 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
View Item |