Fan, Wanlin ORCID: 0000-0001-7143-6707 (2023). Validation of the Portable Next-Generation VECTRA H2 3D Imaging System for Periocular Anthropometry. PhD thesis, Universität zu Köln.

[img] PDF
Thesis_Final_version.pdf - Accepted Version

Download (1MB)

Abstract

Purpose: Portable three-dimensional imaging systems are becoming increasingly common for facial measurement analysis. However, the reliability of portable devices may be affected by the necessity to take three pictures at three time points. The purpose of this study was to evaluate the effectiveness of portable devices for assessing the periocular region. Methods: In 60 Caucasian volunteers (120 eyes), four facial scans (twice for each instrument) using the portable VECTRA H2 and static VECTRA M3 devices were performed; patients’ heads were kept straight, looking ahead, with a neutral facial expression. One assessor set 52 periocular landmarks in the periocular area of each image and subsequently assessed intra- and inter-device reliability by comparing two within-device measurements and one between-device measurement, respectively. Results: The mean absolute difference (MAD) (0.13 and 0.12 units), relative error of measurement (REM) (0.61% and 0.68%), technical error of measurement (TEM)(1.02 and 0.80 units), relative TEM (rTEM) (5.51% and 4.43%), and intraclass correlation coefficient (ICC) (0.89, 0.89) showed good intra-device reliability for M3 and H2; MAD (0.63, 0.62 units), REM (2.83%, 2.69%), TEM (1.31, 1.10 units), rTEM (7.62%, 5.57%) and ICC (0.79, 0.83) indicated that inter-device reliability deteriorated compared to intra-device reliability and that the inter-device reliability of the first scan (moderate) was lower than that of the average of the two scans (good). Conclusions: The portable VECTRA H2 device proved reliable in assessing most periocular linear distances, curve distances, and angles; some improvement in inter-device reliability can be achieved by using the average of two scans.

Item Type: Thesis (PhD thesis)
Translated title:
TitleLanguage
Validierung des tragbaren VECTRA H2 3D-Bildgebungssystems der nächsten Generation für die periokulare AnthropometrieGerman
Creators:
CreatorsEmailORCIDORCID Put Code
Fan, Wanlinfwl900506@163.comorcid.org/0000-0001-7143-6707UNSPECIFIED
Contributors:
ContributionNameEmail
AuthorFan, Wanlinfwl900506@163.com
URN: urn:nbn:de:hbz:38-711078
Date: 25 September 2023
Language: English
Faculty: Faculty of Medicine
Divisions: Faculty of Medicine > Augenheilkunde > Klinik und Poliklinik für Allgemeine Augenheilkunde
Subjects: Medical sciences Medicine
Uncontrolled Keywords:
KeywordsLanguage
three-dimensional anthropometryEnglish
portable stereophotogrammetry devicesEnglish
validityEnglish
reliabilityEnglish
periocular morphologyEnglish
Date of oral exam: 30 June 2023
Referee:
NameAcademic Title
Heindl, Ludwig M.Universitätsprofessor
Widder, RandolfPrivatdozent
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/71107

Downloads

Downloads per month over past year

Export

Actions (login required)

View Item View Item