Wingen, Sabine ORCID: 0000-0002-7444-956X, Großfeld, Nele, Adams, Niels-Benjamin, Streit, Antonia, Stock, Jan, Böttiger, Bernd W. ORCID: 0000-0001-8000-8931 and Wetsch, Wolfgang A. ORCID: 0000-0001-5800-6665 (2024). Do laypersons need App-linked real-time feedback devices for effective resuscitation? – Results of a prospective, randomised simulation trial. Resuscitation Plus, 18. pp. 1-7. Elsevier. ISSN 2666-5204

[thumbnail of 1-s2.0-S2666520424000821-main.pdf] PDF
1-s2.0-S2666520424000821-main.pdf
Bereitstellung unter der CC-Lizenz: Creative Commons Attribution.

Download (331kB)
Identification Number:10.1016/j.resplu.2024.100631

Abstract

[Artikel-Nr.: 100631] Background: App-linked real-time feedback-devices for cardiopulmonary resuscitation (CPR) aim to improve laypersons’ resuscitation quality. Resuscitation guidelines recommend these technologies in training settings. This is the first study comparing resuscitation quality of all App- linked feedback-devices currently on market. Methods: A prospective randomised simulation study was performed. After standardised instructions, participants performed 2-minutes compression-only CPR on a manikin without feedback (baseline). Afterwards, participants performed 4 x 2 min CPR with four different feedback devices in randomised order (CorPatchÒ Trainer, CPRBAND AIO Training, SimCPRÒProTrainer, Relay ResponseTM) (intervention). CPR metrics (chest compression depth (CD), chest compression rate (CR), percentage of correct CD/CR (%), correct hand position, correct chest recoil, and technical preparation-time) were assessed. Devices data were compared to the baseline group using Wilcoxon testing with IBM SPSS (primary outcome). Differences between devices were analysed with ANOVA testing (secondary outcome). Normally distributed data were described as mean ± standard deviation (SD) and non-normally distributed data as Median [Interquartile range (IQR). CPR self-confidence was measured by means of questionnaire before and after feedback devices’ use. Comparison was performed by students t-test. Results: Forty participants were involved. SimCPRÒProTrainer was the only device, which resulted in guideline-compliant chest compressions (Mean ± SD:5.37 ± 0.76) with improved chest compression depth (p < 0.001), and percentage of correct chest compression depth (p < 0.001) com- pared to unassisted CPR (baseline). CorPatchÒ Trainer as the only device with audio-visual recoil instructions resulted in improved chest recoil (Mean ± SD:72.25 ± 24.89) compared to baseline (Mean ± SD:49.00 ± 42.20; p < 0.01), while the other three devices resulted in significantly lower chest recoil rates (CPRBAND AIO Training: 37.03 ± 39.90; p < 0.01, SimCPRÒProTrainer: Mean ± SD:39.88 ± 36.50; p = 0.03, Relay ResponseTM: Mean ± SD:36.88 ± 37.73; p = 0.02). CPR quality when using the different feedback devices differ in chest compression depth (p = 0.02), chest compression rate (p < 0.001), percentage of correct chest compression depth/rate (p = 0.03/p = 0.04), and technical preparation-time (p < 0.001). Feedback-devices’ use increased participant’s CPR self-confidence (p < 0.001). Conclusion: Although, CPR feedback devices show improved CPR performance in layperson in some metrics, none of the tested CPR feedback devices supported layperson in overall adequate CPR performance. More and better technical functionality is necessary, to fully utilise the potential of CPR feedback devices and to prevent a worsening of CPR performance when layperson use this technology.

Item Type: Article
Creators:
Creators
Email
ORCID
ORCID Put Code
Wingen, Sabine
UNSPECIFIED
UNSPECIFIED
Großfeld, Nele
UNSPECIFIED
UNSPECIFIED
UNSPECIFIED
Adams, Niels-Benjamin
UNSPECIFIED
UNSPECIFIED
UNSPECIFIED
Streit, Antonia
UNSPECIFIED
UNSPECIFIED
UNSPECIFIED
Stock, Jan
UNSPECIFIED
UNSPECIFIED
UNSPECIFIED
Böttiger, Bernd W.
UNSPECIFIED
UNSPECIFIED
Wetsch, Wolfgang A.
UNSPECIFIED
UNSPECIFIED
URN: urn:nbn:de:hbz:38-814084
Identification Number: 10.1016/j.resplu.2024.100631
Journal or Publication Title: Resuscitation Plus
Volume: 18
Page Range: pp. 1-7
Number of Pages: 7
Date: June 2024
Publisher: Elsevier
ISSN: 2666-5204
Language: English
Faculty: Faculty of Medicine
Divisions: Faculty of Medicine > Anästhesiologie und Operative Intensivmedizin > Klinik für Anästhesiologie und Operative Intensivmedizin
Subjects: Medical sciences Medicine
Uncontrolled Keywords:
Keywords
Language
Basic Life Support (BLS) ; Cardiopulmonary resuscitation (CPR) ; Cardiac arrest ; Real-time feedback ; Training, Mobile applications ; Mobile health ; Smartphone
English
['eprint_fieldname_oa_funders' not defined]: Publikationsfonds UzK
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/81408

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item