Hohendorff, Bernd, Sauer, Henning, Biber, Franz, Franke, Joerg, Mueller, Lars Peter and Ries, Christian (2019). Radiation exposure caused by the OrthoScan mini C-arm in hand surgery: a one-year case series. Handchir. Mikrochir. Plast. Chir., 51 (3). S. 177 - 185. NEW YORK: THIEME MEDICAL PUBL INC. ISSN 1439-3980

Full text not available from this repository.

Abstract

Background Mobile X-ray imaging systems are standard in the operating theatre. Mini-C-arms are the prevailing technology in hand surgery. Unfortunately, the exposure to Mini-C-arm radiation is often underestimated. Methods For one year, the intraoperative radiation dose delivered by an OrthoScan High Definition Mini-C-arm with a flat panel detector was measured using headband and finger ring dosimeters in all hand and wrist surgeries performed by three experienced hand surgeons. Results Two hundred and thirteen patients underwent surgical treatment involving the use of an OrthoScan High Definition Mini-C-arm. The total radiation dose administered by all three hand surgeons over 12 months was 9033.39 mGy with a total irradiation time of 376:38 min. A radiation exposure of 2.0 mSv was detected on both finger ring dosimeters of one surgeon during one month. For all other dosimeters, the monthly radiation exposure was below the detection limit of Conclusion The radiation exposure reached during about 100 surgeries/surgeon/year involving the use of an OrthoScan Mini-C-arm does not exceed the annual occupational exposure limits of 50 mSv for the hand and 20 mSv for the lens of the eye. Only at an X-ray exposure of 800-1000 mGy/month can radiation exposure be detected with a finger ring dosimeter (measuring range 0.3 mSv-10 Sv) in a hand surgeon. Due to the potential health risk posed by stochastic radiation effects, all possible safeguards including behavioural measures should be observed.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Hohendorff, BerndUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Sauer, HenningUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Biber, FranzUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Franke, JoergUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Mueller, Lars PeterUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Ries, ChristianUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-138492
DOI: 10.1055/a-0898-3618
Journal or Publication Title: Handchir. Mikrochir. Plast. Chir.
Volume: 51
Number: 3
Page Range: S. 177 - 185
Date: 2019
Publisher: THIEME MEDICAL PUBL INC
Place of Publication: NEW YORK
ISSN: 1439-3980
Language: German
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
IONIZING-RADIATION; RISKSMultiple languages
SurgeryMultiple languages
Refereed: Yes
URI: http://kups.ub.uni-koeln.de/id/eprint/13849

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item