Goertz, Lukas, Stavrinou, Pantelis, Stranjalis, George, Timmer, Marco, Goldbrunner, Roland and Krischek, Boris (2020). Single-Step Resection of Sphenoorbital Meningiomas and Orbital Reconstruction Using Customized CAD/CAM Implants. Journal of Neurol. Surg. Part B, 81 (2). S. 142 - 149. NEW YORK: THIEME MEDICAL PUBL INC. ISSN 2193-634X

Full text not available from this repository.

Abstract

Objective Computer-aided design and manufacturing (CAD/CAM) implants are fabricated based on volumetric analysis of computed tomography (CT) scans and are routinely used for the reconstruction of orbital fractures. We present three cases of patients with sphenoorbital meningiomas that underwent tumor resection, orbital decompression, and orbital reconstruction with patient specific porous titanium or acrylic implants in a single procedure. Methods The extent of bone resection of the sphenoorbital meningiomas was planned in a virtual three-dimensional (3D) environment using preoperative thin-layer CT data. The anatomy of the orbital wall in the resection area was reconstructed by superimposing the contralateral unaffected orbit and by using the information of the neighboring bony structures. The customized implants and a corresponding craniotomy template were designed in the desired size and shape by the manufacturer. Results All patients presented with a sphenoorbital meningioma and exophthalmos. After osteoclastic craniotomy with the drilling template, orbital decompression was performed. Implant fitting was tight in two cases and could be easily fixated with miniplates and screws. In the third patient, a reoperation was necessary for additional bone resection, as well as drilling and repositioning of the implant. The postoperative CT scans showed an accurate reconstruction of the orbital wall. After surgery, exophthalmos was substantially reduced and a satisfying cosmetic result could be finally achieved in all patients. Conclusions The concept of preoperative 3D virtual treatment planning and single-step orbital reconstruction with CAD/CAM implants after tumor resection involving the orbit is well feasible and can lead to good cosmetic results.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Goertz, LukasUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Stavrinou, PantelisUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Stranjalis, GeorgeUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Timmer, MarcoUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Goldbrunner, RolandUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Krischek, BorisUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-339056
DOI: 10.1055/s-0039-1681044
Journal or Publication Title: Journal of Neurol. Surg. Part B
Volume: 81
Number: 2
Page Range: S. 142 - 149
Date: 2020
Publisher: THIEME MEDICAL PUBL INC
Place of Publication: NEW YORK
ISSN: 2193-634X
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
PREFABRICATED TITANIUM IMPLANTS; CRANIOPLASTY; DEFECTS; SURGERY; DESIGNMultiple languages
Clinical Neurology; SurgeryMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/33905

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item