Zinser, Max and Zoeller, Joachim (2015). Computer-Designed Splints for Surgical Transfer of 3D Orthognathic Planning. Facial Plast. Surg., 31 (5). S. 474 - 491. NEW YORK: THIEME MEDICAL PUBL INC. ISSN 1098-8793

Full text not available from this repository.

Abstract

Advances in computers and imaging have permitted the adoption of three-dimensional (3D) planning protocols in orthognathic surgery, which may allow a paradigm shift when the computer-assisted planning can be transferred properly. The purpose of this investigation was to introduce an innovative clinical protocol using computer-aided designed and computer-aided manufactured (CAD/CAM) surgical splints for surgical transfer of 3D orthognathic planning compared with the classic technique using arbitrary occlusal splints. The clinical protocols consisted of computed tomography (CT) or cone-beam CT (CBCT) maxillofacial imaging, bone segmentation, 3D diagnosis, computer-assisted surgical treatment planning, and CAD/CAM surgical splints (group A) and manufacture of arbitrary occlusal splints (group B) for intraoperative surgical planning transfer. The observed patients underwent bimaxillary osteotomies and, if necessary, an additional genioplasty. Both techniques were evaluated by applying 13 hard tissue parameters to compare the 3D orthognathic planning (T-0) with the postoperative result (T-1) using 3D cephalometry. The CAD/CAM splints showed significant better precision for the maxilla (T<0.23 mm) and mandible (T<0.33 mm) compared with a maxillary deviation of 1.3mm and a mandibular deviation of 1.8mm when using the arbitrary splints. Computer-assisted diagnosis and preoperative surgical planning provide clinicians with valuable tools and allow 3D imagination. CAD/CAM splints provide a reliable, innovative, and precise approach for the transfer of 3D orthognathic planning, which is more precise compared with the conventional arbitrary occlusal splints.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Zinser, MaxUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Zoeller, JoachimUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-390344
DOI: 10.1055/s-0035-1565010
Journal or Publication Title: Facial Plast. Surg.
Volume: 31
Number: 5
Page Range: S. 474 - 491
Date: 2015
Publisher: THIEME MEDICAL PUBL INC
Place of Publication: NEW YORK
ISSN: 1098-8793
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
FACE-BOW TRANSFER; INTRAOPERATIVE NAVIGATION; NUMERICAL-SIMULATION; CLASS-II; SURGERY; ACCURACY; TOMOGRAPHY; SUPERIMPOSITION; ADVANCEMENT; PRECISIONMultiple languages
SurgeryMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/39034

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item