Ecker, Hannes, Kolvenbach, Simone, Herff, Holger and Wetsch, Wolfgang A. (2021). Intubation using VieScope vs. Video laryngoscopy in full personal protective equipment - a randomized, controlled simulation trial. BMC Anesthesiol., 21 (1). LONDON: BMC. ISSN 1471-2253

Full text not available from this repository.

Abstract

Background: VieScope is a new type of laryngoscope, with a straight, transparent and illuminated blade, allowing for direct line of sight towards the larynx. In addition,VieScope is disposed of after single patient use, which can avoid cross-contaminations of contagious material. This has gained importance especially when treating patients with highly contagious infectious diseases, such as during the SARS-CoV2 pandemic. In this context, VieScope has not been evaluated yet in a clinical study. Material and methods: This study compared intubation with VieScope to video-laryngoscopy (GlideScope) in normal and difficult airway in a standardized airway manikin in a randomized controlled simulation trial. Thirty-five medical specialists were asked to perform endotracheal intubation in full personal protective equipment (PPE). Primary endpoint was correct tube position. First-pass rate (i.e., success rate at the first attempt), time until intubation and time until first correct ventilation were registered as secondary endpoints. Results: For correct tracheal tube placement, there was no significant difference between VieScope and GlideScope in normal and difficult airway conditions. VieScope had over 91% fist-pass success rate in normal airway setting. VieScope had a comparable success rate to GlideScope in difficult airway, but had a significantly longer time until intubation and time until ventilation. Conclusion: VieScope and GlideScope had high success rates in normal as well as in difficult airway. There was no unrecognized esophageal intubation in either group. Overall time for intubation was longer in the VieScope group, though in an acceptable range given in literature. Results from this simulation study suggest that VieScope may be an acceptable alternative for tracheal intubation in full PPE.

Item Type: Journal Article
Creators:
CreatorsEmailORCIDORCID Put Code
Ecker, HannesUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Kolvenbach, SimoneUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Herff, HolgerUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Wetsch, Wolfgang A.UNSPECIFIEDUNSPECIFIEDUNSPECIFIED
URN: urn:nbn:de:hbz:38-569105
DOI: 10.1186/s12871-021-01502-7
Journal or Publication Title: BMC Anesthesiol.
Volume: 21
Number: 1
Date: 2021
Publisher: BMC
Place of Publication: LONDON
ISSN: 1471-2253
Language: English
Faculty: Unspecified
Divisions: Unspecified
Subjects: no entry
Uncontrolled Keywords:
KeywordsLanguage
GLIDESCOPE(R)Multiple languages
AnesthesiologyMultiple languages
URI: http://kups.ub.uni-koeln.de/id/eprint/56910

Downloads

Downloads per month over past year

Altmetric

Export

Actions (login required)

View Item View Item